TECHNICAL DOCUMENTATION

according Directive 2010/30/EU and corresponding Regulation (EU) No. 811/2013 (Energy Labelling),
Dircetive 2009/125/EC and corresponding Regulation (EU) No. 813/2013 (Ecodesign)
Model:
Type of heat pump:
Low-temperature heat pump: (Yes/No)
Temperature application: (35°C/55°C)
Equipped with supplementary heater: (Yes/No)
Heat pump combination heater: (Yes/No)
Rated heat output
Outdoor temperature T
j
T
= – 15 °C
j
T
= – 7 °C
j
T
= +2 °C
j
T
= +7 °C
j
T
= +12 °C
j
T
= Bivalenz temperature (T
)
j
biv
T
= Operation limit temperature (TOL)
j
Bivalenz temperature (Tbiv)
Cycling interval capacity for heating
Degradation co-efficient
Power consumption in modes other than active mode
Thermostat-off mode
Standby mode
Off-mode
Crankase heater mode
Other items
Capacity control
Sound power levels, indoors/outdoors
Annual energy consumption
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Annual electricity consumption
Contact details:
IDM-Energiesysteme, Seblas 16-18, 9971 Matrei i.O., Austria
ALM 2-8
Air-to-water heat pump
Yes
low temperature (35°C)
Yes
Yes
Climate condition
cold
average
warm
8,4
7,7
7,7
kW
Declared capacity for part load
(indoor temperature = 20 °C)
P
6,9
-
-
kW
dh
P
5,1
6,8
-
kW
dh
P
3,1
4,2
7,7
kW
dh
P
2,4
2,8
5,0
kW
dh
P
2,6
2,8
2,6
kW
dh
P
6,9
7,7
8,3
kW
dh
P
6,2
7,7
8,3
kW
dh
T
-15,0
-10,0
2,0
°C
biv
P
kW
cych
C
0,990
1,00
0,99
---
dh
P
0,029
0,029
0,029
kW
TO
P
0,029
0,029
0,029
kW
SB
P
0,001
0,001
0,001
kW
OFF
P
0
0
0
kW
CK
variable
L
45,5
45,5
45,5
dB
WA
Q
4 632
3 023
1 588
kWh
HE
n.a.
Q
n.a.
kWh
elec
n.a.
AEC
kWh
Seasonal space heating efficiency
Outdoor temperature Tj
T
= – 15 °C
j
T
= – 7 °C
j
T
= +2 °C
j
T
= +7 °C
j
T
= +12 °C
j
T
= Bivalenz temperature (T
)
j
biv
T
= Operation limit temperature (TOL)
j
Operation limit temperature
Cycling interval capacity for heating
Heating water operating limit temperature
Supplementary heater
Rated heat output (*)
Type of energy input
For air-to-water heat pumps:
Rated air flow rate, outdoors
For water- or brine-to-water heat pumps:
Rated brine or water flow rate, outdoor heat exchanger
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
Climate condition
cold
average
warm
176
207
256
%
s
Declared capacity for part load
(indoor temperature = 20 °C)
COP
2,34
-
-
---
d
COP
3,68
3,02
-
---
d
COP
5,82
5,18
3,13
---
d
COP
7,52
7,08
5,91
---
d
COP
8,15
9,10
8,15
---
d
COP
2,34
2,48
2,90
---
d
COP
2,06
2,48
2,90
---
d
TOL
-20,0
-10,0
2,0
°C
COP
---
cyc
WTOL
70
70
70
°C
P
1-6
1-6
1-6
kW
sup
electrical
3
---
2 000
2 000
2 000
m
/h
3
---
n.a.
n.a.
n.a.
m
/h
n.a.
%
Q
n.a.
n.a.
n.a.
kWh
fuel
AFC
n.a.
n.a.
n.a.
GJ
Rev.0/01-12-2016