Herunterladen Inhalt Inhalt Diese Seite drucken

Product Description; Set-Up; Technical Specifications; Normative References - Cleco CellCore 200 Serie Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3

Product Description

Each controller is to be used as a control and monitoring
device for one or more tools at a workstation. Desktop soft-
ware is available to enable management of the controller
remotely.
Each controller comes with software pre-installed. The
minimum settings for bolt connections must be carried out
by a qualified person using the controller or a PC to start
fastening.
4

Set-Up

Each Series 200 Controller has been pre-loaded with an
IP address of 192.168.100.200 (Connection X1 / ETH1)
Note
If installing more than one Series 200 Con-
troller, each controller must have a unique
IP address. Connecting all controllers to the
same network without changing the original
IP address of 192.168.100.200 will create
an IP conflict.
 Assign a new IP address to each
controller.
There are three ways to program the Series 200 Controller:
Direct Connect Using a Laptop/PC
1.
Download and install mProRemote Software
(www.ClecoSoftware.com) on any laptop/PC.
2.
Connect laptop/PC directly to a Series 200 Controller
using an Ethernet cable.
3.
Set network settings from laptop/PC to i. e.
192.168.100.201.
4.
Follow instructions provided with mProRemote.
Connect in Existing Network
1.
Consult your IT Department before connecting any
equipment to the plant network.
2.
Download and install mProRemote Software
(www.ClecoSoftware.com) on any laptop/PC.
3.
Connect controller to the plant network via Ethernet
cable. PC must be on the same network as the
Series 200 Controller to begin setup.
4.
Follow instructions provided with mProRemote.
From The Controller
1.
Attach a monitor, keyboard and mouse to the
Series 200 Controller.
For more detailed installation instructions, see Quick Instal-
lation P2402K.
Apex Tool Group GmbH
5

Technical specifications

Ambient conditions
Features
Operation site
Ambient temperature
Storage temperature
Type of cooling
Relative humidity
Working height
Degree of protection
DIN EN 60529 (IEC
60529)
Protection class
DIN EN61140
(VDE0140-1)
Degree of contamination
EN 61010
Transient overvoltage
EN 61010
Shock max.
DIN EN 60068-2-27
Vibration max.
DIN EN 60068-2-5
Power supply
Features
Supply voltage
single-phase
Rated supply current
Frequency
Peak current
Rated power
Idling

5.1 Normative References

Product-relevant EC directives and the standards complied
with, see EC Declaration of Conformity.
Weight (incl. cable)
Model
Serie 200
Serie 200-G
Serie 200-AP
Serie 200-AP-G
2019-01
P2403HW |
Data
Indoors
0...45 °C
-20...70 °C
Convection (self-cooling)
10 – 90%, no condensa-
tion
Up to 3000 m (9,843 ft)
above sea level
IP42
I
2

CAT
15 G
59.6–160 Hz: 2 G
Data
90–264 VAC ±10%
0,5 A
47–63 Hz
0,5 A
60 VA max.
60 VA
lb
kg
7.1
3,23
7.5
3,43
17
2
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis