Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Parameters; Other Information - Elko EP PDR-2/A Anleitung

Digitales zeitrelais - programmierbar
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22

Technical parameters

Function:
Supply terminals:
Voltage range:
AC/DC 12-240V
(AC 50-60 Hz)
Power input max.
AC 0.5-2.5 VA/
(apparent / loss):
DC 0.4 - 2.5 W
Max. dissipated power
(Un + terminals):
Supply voltage tolerance:
Time ranges:
Repeat accuracy:
Temperature coeffi cient:
Time data
Time range:
Minimal time step:
Time deviation:
Setting error:
Setting, reset accuracy:
Digital places:
Output
Number of contacts:
Current rating:
Breaking capacity:
Inrush current:
Switching voltage:
Output indication:
Mechanical life:
Electrical strength (AC1):
Control
Power the control input:
AC 0.01-0.25 VA
Glow tubes connetions:
Impulse length:
Reset time:
Display - colour:
Number and height of digits:
4 positions with separating colon, height 10 mm (0.39˝)
Luminace:
Light wavelength:
Brightness setting:
Memory - memory
locations:
Data stored for:

Other information

Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Max. cable size (mm
2
):
Dimensions:
Weight:
140 g (4.9 oz.)
Standards:
PDR-2/A
PDR-2/B
UNI
230 V
UNI
16
A1 - A2
AC 230 V/
AC/DC 12-240V
50-60 Hz
(AC 50-60 Hz)
AC16 VA /
AC 0.5-2.5 VA/
2.5 W
DC 0.4 - 2.5 W
5.5 W
-15 %; +10 %
0.01 s - 100 h
0.2 % - set value stability
0.01 % / °C, at = 20 °C (0.01 % / °F, at = 68 °F)
0.01 s - 99 h 59 min 59 sec 99 ss
0.01 s
0.01 % of set value
0 %
100 %
selected via program
2x changeover / SPDT (AgNi / Silver Alloy)
16 A / AC1
4000 VA / AC1, 384 W / DC
30 A / < 3 s
250 V AC / 24 V DC
red LED
3x10
7
0.7x10
5
AC 0.25 VA
AC 0.01-0.25 VA
No
min. 1 ms / max. unlimited
max. 200 ms
red
2200 - 3800 ucd
635 nm
range 20 - 100 % in 10 steps adjustable
30 for times ranges
20 for times ranges
+ service function
+ service function
min. 10 years
-20 °C to 55 °C (-4 °F to 131 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
4 kV (supply - output)
any
DIN rail EN 60715
IP40 from front panel / IP20 terminals
III.
2
solid wire max. 1x 2.5 or 2x 1.5 /
with sleeve max. 1x 1.5 (AWG 12)
90 x 52 x 65 mm (3.5˝ x 2˝ x 2.6˝)
142 g (5 oz.)
140 g (4.9 oz.)
EN 61812-1, EN 61010-1
Warning
Device is constructed for connection in 1-phase main alternating current voltage and must
be installed according to norms valid in the state of application. Connection according to the
230 V
details in this direction. Installation, connection, setting and servicing should be installed by
qualifi ed electrician staff only, who has learnt these instruction and functions of the device. This
10
device contains protection against overvoltage peaks and disturbancies in supply. For correct
function of the protection of this device there must be suitable protections of higher degree
AC 230 V/
(A, B, C) installed in front of them. According to standards elimination of disturbancies must be
ensured. Before installation the main switch must be in position "OFF" and the device should be
50-60 Hz
de-energized. Don´t install the device to sources of excessive electro-magnetic interference.
AC 16 VA /
By correct installation ensure ideal air circulation so in case of permanent operation and higher
2.5 W
ambient temperature the maximal operating temperature of the device is not exceeded. For
installation and setting use screw-driver cca 2 mm. The device is fully-electronic - installation
should be carried out according to this fact. Non-problematic function depends also on the
way of transportation, storing and handling. In case of any signs of destruction, deformation,
non-function or missing part, don´t install and claim at your seller it is possible to dismount the
device after its lifetime, recycle, or store in protective dump.
AC 0.25 VA
142 g (5 oz.)
3 / 3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pdr-2/b

Inhaltsverzeichnis