Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Care - T.I.P. SPU 36000 Gebrauchsanweisung

Uv-c strahler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
filter...). Observe the lamp's direction of flow (see image). Only connect the lamp to
a system that does not exceed the maximum flow rate and pressure specified in the
technical information.
Placing in service
Attention! Comply with the safety measures specified for the UVC emitter
(see above)! (See the provided operating instructions).
Install the connection socket outlet in the water-protected area and at least 2
m away from the edge of the pond!
Check whether the hose/pipe connections are waterproof, and that no leaks are
visible on lamp. Check that no one is in the water.
Connect the UVC emitter to the mains supply, plug the mains plug into the socket
outlet.
You can check the function of the UVC tubes through a bluish shimmer on the
transparent covers.
Operation
We recommend only operating the UVC lamp during the season when there is no
danger of people being in the water.

6. Maintenance and care

Attention! Before performing any installation or maintenance tasks, disconnect the
electrical devices immersed in the pond from the power source by pulling the plug
out of the socket outlet.
Attention! If the UVC unit's power cable is damaged, it must be placed by the
manufacturer or their customer service, or by a similar qualified person, to prevent
hazards.
16
Check the complete scope of delivery by taking all the
packaging material out of the package.
Mount the hose connections (5) on the inlet and outlet (see
left image) of the UVC lamp by manually screwing in a hose
connector with seal, tightly in each place. Make sure the
seal is seated correctly. The UV lamp should be affixed on a
sturdy base. Fasten the lamp at the fastening points
provided for this (15), using two screws in a place safe from
flooding and protected from rain. Ensure that the lamp is not
exposed to direct sunlight or frost. The lamp should be
installed horizontally; all other positions are prohibited for
safety reasons.
Connect the UVC lamp to your filter system (hoses, pump,
5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis