BATTERY CHECK/SETTING ON A NEW MACHINE

WARNING!
The electric components of the machine can be seriously
damaged if the batteries are either improperly installed or
connected. The batteries must be installed by qualified per-
sonnel only. Set the battery type using the procedure below
according to the type of batteries used (WET or
GEL/AGM/DIS batteries). Check the batteries for damage
before installation. Disconnect the battery connector and
the battery charger plug. Handle the batteries with great
care. Install the battery terminal protection caps supplied
with the machine.
NOTE
The machine requires six 6V batteries, con-
nected and installed in the positions shown in
Figure 5.
Batteries already installed on the machine
1.
Ensure that the battery connector is connected.
2.
When first using the machine with new batteries, perform a full charging cycle (see the procedure in Maintenance chapter).
Without batteries
1.
Buy appropriate batteries (see "Technical Data" paragraph). For battery choice and installation, contact qualified battery Retailers.
2.
Set the battery type setting using the procedure below.
BATTERY INSTALLATION AND BATTERY TYPE SETTING (WET /GEL/ AGM/ DIS)

Battery installation

1.
Open the left and right latches (7, Figure 1).
2.
Open the recovery tank lid (5, Figure 1) and check that the recovery tank (8, Figure 1) is empty; otherwise empty it with the drain
hose (38, Figure 2).
3.
Close the recovery tank lid (5, Figure 1).
4.
Raise the recovery tank (8, Figure 1) carefully.
5.
Disconnect the recovery tank cable and remove the whole recovery tank assembly.
6.
Remove one screw of the recovery tank turning cable (31, Figure 2) and turn back.
7.
Remove recovery tank four screws on the bottom of it.
The machine is supplied with cables suitable to install six 6V batteries. Carefully put the batteries into the compartment, then install
them correctly as shown in Figure 5. Put the battery fixed plate correctly.
8.
Route and install the battery cable as shown in Figure 5, then carefully tighten the nut on each battery terminal.