Table 1 - VERSION 1
Max consumption (mA, RMS)
DIP setting
Pattern
Nominal Frequency
Paramètre DIP
No
Type
Fréquence nominale
Consommation max. (mA, RMS)
DIP-Schaltereinstellung
Muster
Nennfrequenz
Maximalverbrauch (mA, RMS)
Impostazione DIP
Schema
Frequenza nominale
Consumo medio (mA, RMS)
Configuración DIP
Patrón
Frecuencia nominal
Consumo máximo (mA, RMS)
SW 1,2,3,4,5
Volume
O=Off/1=On
0,0,0,0,0
1
Alternating
525/440
1,0,0,0,0
2
Alternating
800/922
0,1,0,0,0
3
Alternating
800/922
1,1,0,0,0
4
Alternating
2400/2900
0,0,1,0,0
5
Alternating
2500/3100
1,0,1,0,0
6
Alternating
988/645
0,1,1,0,0
7
Continuous
630
1,1,1,0,0
8
Continuous
922
0,0,0,1,0
9
Continuous
1200
1,0,0,1,0
10
Continuous
2810
0,1,0,1,0
11
Sweep
150-1000
1,1,0,1,0
12 Intermittent
420
0,0,1,1,0
13
Sweep
500-1200
1,0,1,1,0
14
Intermittent
630
0,1,1,1,0
15
Intermittent
922
1,1,1,1,0
16
Intermittent
922
0,0,0,0,1
17
Intermittent
2810
1,0,0,0,1
18
Intermittent
922
0,1,0,0,1
19
Intermittent
950
1,1,0,0,1
20
Continuous
800
0,0,1,0,1
21
Sweep
400-1200
1,0,1,0,1
22
Sweep
1200 - 500
0,1,1,0,1
23
Sweep
2400 - 2850
1,1,1,0,1
24
Sweep
500 - 1200
0,0,0,1,1
25
Sweep
800 - 970
1,0,0,1,1
26
Sweep
800 - 970
0,1,0,1,1
27
Sweep
800 - 970
1,1,0,1,1
28
Sweep
2400 – 2850
0,0,1,1,1
29
Sweep
500 – 1000
1,0,1,1,1
30
Sweep
500 – 1200 – 500
0,1,1,1,1
31
Sweep
800 – 1000
1,1,1,1,1
32
Sweep
2400 - 2850
Volume, coverage and frequency settings
(Refer to table 1 ) (Refer to table 2 )
DIP setting 0=Off/1=On
Paramètre DIP 0=Désactivé/1=Activé
1
ON
DIP-Schaltereinstellung
1 2 3 4 5 6 7 8
O=Aus/1=Ein
Impostazione DIP 0=Off/1=On
0
Configuración DIP
0=Desactivado/1=Activado
Table 2
ON
OFF
SW6
LOW VOLUME
HIGH VOLUME
SW7 N/A
not in use
not in use
SW8
f
1Hz (Open class only) 0.5Hz
KAC ALARM COMPANY LIMITED, KAC House, Thornhill Road, Redditch, Worcestershire, England. B98 9ND. www.kac.co.uk
Switching Frequency
Fréquence de commutation
Frequenzwechsel
Beschreibung
Frequenza di commutazione
Frecuencia de conmutación
Volume
French Fire Sound
19.89
14.43
2Hz (100ms/400ms)
18.28
14.68
1Hz
18.28
14.68
2Hz
Alternating tone telecoms
Alternating High
18.47
15.24
3Hz
24.53
15.11
2Hz
Security Alarm
19.7
14.77
2Hz
19.51
14.25
18.4
14.71
19.48
14.27
18.74
15.03
HF Continuous
Rising from 150Hz to 1000Hz in 10
seconds, then 40 seconds at
1000Hz, then falling from 1000Hz to
19.93
14.52
"Gasalarm" Tone
150Hz in 10 seconds, then 20
seconds at 150Hz, then repeating.
Total period 80 seconds.
19.29
14.08
0.625s on, 0.625 sec off
AS2220 alert tone
19.12
14.06
0.25 sec off, 3.75 sec on
AS2220 evacuate tone
19.51
14.25
3.33Hz 150ms on, 150ms off
Swedish alarm tone
18.4
14.71
0.8Hz 0.25s on, 1s off
Intermittent Tone
Back up alarm LF &
18.4
14.71
0.5Hz 1s on, 1s off
Back up alarm HF &
18.74
15.03
1Hz
BS5839 Pt 1 2nd tone
18.4
14.71
1Hz 500ms on, 500ms off
LF BS5839 Pt 1
0.22Hz (0.5s on, 0.5s off) rptx3, 1.5s
19.64
14.55
off
18.03
13.93
Temporal 3 Evacuation
18.67
14.29
(0.5s on, 0.5s off)*3, 1.5s off
Evacuate, DIN tone &
18.98
13.97
0.99Hz 1s on, 0.01s off
18.47
15.24
7Hz
Fast sweep VdS
Slow whoop evacuate
18.98
15.19
(0.5s off, 3.5s on)
18.2
14.89
50Hz
LF Buzz BS5839 Pt 1
Fast sweep LF BS5839 Pt
17.31
14.32
7Hz
Medium sweep LF,
18.06
14.22
1Hz
BS5839 Pt 1, VdS
18.47
15.24
50Hz
High frequency buzz
18.13
14.06
7Hz
19.73
14.81
0.166Hz rise 1s, stable 4s, fall 1s
Siren style tone
19.48
14.39
2Hz
19.28
15.15
1Hz
Address settings
Switch 1
Contact 1
Schalter 1
Interruttore 1
Interruptor 1
Description
Market
Standard
2nd Stage Tone
Description
Marché
Standard
Tonalité de 2ème niveau
Markt
Standard
Ton der zweiten Stufe
Descrizione
Mercato
Norma
Tono di seconda fase
Descripción
Mercado
Norma
Tono de 2.ª fase
France
NFS 32-001
7
AFNOR
UK
BS5839 Pt1
8
BS5839 Pt1,
UK
8
FP1063.1
10
Frequency
10
8
All clear
Sweden
1
BS 5839 Pt 1
2
2
4
22
NZ, Aus
AS2220
13
NZ, Aus
AS2220
12
Sweden
7
UK
BS 5839 Pt 1
8
UK
BS5839 Pt 1
8
BS5839 Pt 1
UK
BS5839 Pt 1
10
UK
BS5839 Pt 1
8
Australia
ISO8201
12
BS 5839 Pt 1
22
ISO8201 Temporal
Australia
12
tone
3
Germany
DIN, PFEER
20
PFEER
Germany
VdS
10
Netherlands
NEN 2575
8
Netherlands
UK
BS5839 Pt 1
8
UK
BS5839 Pt 1
8
1
UK, Germany BS5839 Pt 1 VdS
8
10
Fast whoop
8
8
8
10
Switch 2
Contact 2
Schalter 2
Interruttore 2
Interruptor 2
S1
S2
Address 108 = 10
8
Adresse 108 = 10
8
Adresse 108 = 10
8
Indirizzo 108 = 10
8
Dirección 108 = 10
8
Typical Sound Output (dB)
Coverage data/ ceiling mount device example
Sortie sonore type (dB)
Typische Tonausgabe (dB)
Uscita audio tipica (dB)
Salida de sonido típico (dB)
EN 54-23
Volume
Volume
C - 3 - 8.5
95.35
81.7
O - 1 - 3
95.39
86.4
95.39
86.4
90.8
83.87
96.99
82.73
97.38
86.23
96.6
83.29
95.39
86.79
97.39
86.79
91.22
85.32
93.82
81.67
96.56
82.04
97.5
83.81
96.6
83.29
95.39
86.79
95.39
86.79
Regulation (EC) No 1907/2006
91.22
85.32
According to Article 33 of REACH Regulation be informed that the substance
95.39
86.79
listed below may be contained in these products above the threshold level of
97
87.32
0.1% by weight of the listed article.
94.83
79.75
Product code Substance Name
95.21
81.14
96.4
82.86
90.8
83.87
96.75
84
This symbol on our product shows a crossed-out "wheelie-bin" as
required by law regarding the Waste of Electrical and Electronic
95.24
85
Equipment (WEEE) disposal. This indicates your responsibility to
94.6
83.15
contribute in saving the environment by proper disposal of this
95.38
84.49
Waste i.e. Do not dispose of this product with your other wastes.
90.8
83.87
To know the right disposal mechanism please check the applicable law
95.68
82.08
97.59
86.94
Sounder Output data, in accordance with EN54-3, is available on Document
97
86.95
Ref: D 1154
92.19
85.63
(ENG)To set one of the 159 available addresses for the
device use the two rotay switches located either side of the
dip switch unit. The `tens` digits goes from
0 to 15 and the `units` from 0 to 9.
*100 - 159 Only available with advanced protocol.
(FRE)Pour régler l'une des 159 adresses disponibles pour le
dispositif, utilisez les deux commutateurs rotatifs situés sur
l'un des côtés de l'unité de commutateurs DIP. Les chiffres
des dizaines vont de 0 à 15 et ceux des unités de 0 à 9.
*100 à 159 Uniquement disponible avec le protocole avancé.
(GER)Verwenden Sie die beiden Drehschalter zu beiden
Seiten der DIP-Schaltereinheit, um eine der 159 verfügbaren
Adressen für das Gerät einzustellen. Die „Zehner"-Ziffern
reichen von 0 bis 15 und die „Einer" von 0 bis 9.
*100–159 stehen nur mit erweiterten Protokoll zur
Verfügung.
(ITA)Per impostare uno dei 159 indirizzi disponibili per il
dispositivo utilizzare i due selettori rotanti posizionati su
entrambi i lati dell'unità DIP switch. Le cifre delle decine
vanno da 0 a 15 e quelle delle unità da 0 a 9.
*100 - 159 Disponibili solo con il protocollo avanzato.
(SPA)Para definir una de las 159 direcciones disponibles en
el dispositivo, utilice los dos selectores giratorios situados a
ambos lados del cuadro de conmutadores de selección. Los
dígitos decimales van del 0 al 15 y las unidades del 0 al 9.
* 100-159 Solo disponible con el protocolo avanzado.
Led
Z
V
X (Max)
V (m ³)
(Max)
RED
15-29V
3m
8.5m
170
RED
15-29V
1
3m
7
CAS Number
Lead
7439-92-1
2831 20
Notifier by Honeywell,
Pittway Tecnologica Srl, Via Caboto 19/3
34147 Trieste, Italy
DOP048NO - ISO
EN 54-3:2001 +A1: 2002 + A2:2006
Fire detection and fire alarm
systems - Sounders
EN54-23:2010
Fire detection and fire alarm
systems - Visual Alarm Devices
EN 54-17:2005
Fire detection and fire alarm
systems - Short-circuit isolators.
NFXI-BSF-WCS
D 1148 Issue 1

Werbung

loading