The shower will last longer if the following parameters are respected: (as required by
Legislative Decree 02/02/2001, n.31: implementation of Directive 98/83 / EC relating to the quality of
water intended for human consumption):
chlorides: maximum value 200 mg / l
pH: between 6.5 and 9.5
conductivity: maximum value 2500 µS / cm
total hardness: between 15 and 30 °F; in the presence of water with a hardness higher than
30 ° F it is recommended to use anti-limescale devices or softeners (the choice must be
made based on the characteristics of the water).
In the presence of water with parameters that do not comply with the above, the manufacturer
reserves the right not to recognize the warranty.
USE
4.
Lift and rotate the mixer handle (FIG-4-1) until the desired water temperature is reached (A:
hot water position – B: cold water position).
Once the mixer is open, the water takes about 15/20 seconds before coming out of the shower head
as it is necessary to wait for the push given by the pressure of the network.
At the end of the use, return the handle to the initial position to stop the water supply. The water will
continue to flow out of the shower head until the thrust previously given by the mains pressure is
exhausted (about 30 seconds).
Warning, danger of burns: always start using the shower with the mixer knob positioned in
cold water position as the temperature inside the shower can reach temperatures above 50 ° C.
Attention: if the shower is not used for more than 3 days it is advisable, before use, to let the
water flow out for about 2 minutes to remove the stagnant water inside the shower
The foot wash tap only delivers cold water
Pag. 12 / 36
ENGLISH
210-0271 – edizione 2020-09