iCon-M233N
Multi Spray Unit |
10.2 USE
IMPORTANT! BEFORE USE of the pump it is IMPORTANT TO READ CAREFULLY and observe the war-
nings and cautions contained in THE INSTRUCTION MANUAL OF THE GUN TO BE USE.
MSGS-200 EVO (with Multi Spray Pump) or ALG-7 TE (with Airless Pump).
1
After Flushing (see 10.1), before to supply air to the pump, confirm that
the ball valve is open and the air regulator is adjusted to 0 bar.
O BAR
OPEN
ICON-M233N
ICON-A233N
3
Open the drain valve for recircula-
4
Set the pressure regulator up slowly, to the minimum pressure required for
tion of fluid.
the straight and alternate movement of the piston.
ICON-M233N
OPEN
5
Ensure that the paint comes out from re-
6
Adjust the air pressure regulator, to the collect FLUID WORKING
circulation hose, then close the drain valve.
PRESSURE.
ICON-M233N
CLOSE
7
Adjust the air pressure regulator to
8
When finished to spray, set the air pressure regulator of the pump at less
collect ATOMIZING PRESSURE.
than 1 bar, then repeat the instruction from points 5 to 8 on page 13.
ICON-M233N
ICON-M233N
OPEN
14
iCon-A233N
Airless Unit
2
Immerse the suction hose in the con-
tainer, containing paint.
OPEN
ICON-A233N
ICON-A233N
OPEN
OPEN
ICON-A233N
1 BAR
OPEN
OPEN
iCon-M233N
Multi Spray Unit |
WARNING!
DURING OPERATION, THE PUMP RELEASES EXHAUST AIR
FROM THE AIR MUFFLER. DO NOT NOT TOUCH THE EXHAUST
BLOCK, WHILE THE PUMP IS OPERATING.
10.3 INCREMENTAL FLUID PRESSURE
Model
RATIO
AIR REGULATOR SETTING
0.3MPa (3bar - 43.5psi)
ICON-M233N
30:1
0.5MPa (5bar - 72.5psi)
ICON-A233N
0.7MPa (7bar - 100psi)
11. ORDINARY MAINTENANCE
11.1 DAILY MAINTENANCE
1 FLUSHING THE PUMP: Clean the pump unit after working and after any color change.
MAKE SURE THERE ARE NO PAINT OR AIR LEAKS: Check that the hoses are not damaged and that all threa-
2
ded connections are firmly tightened. Intervene immediately if you find any anomalies and replace it in case of
damage.
11.2 MONTHLY MAINTENANCE
CHECK THE SUCTION HOSE FILTER: Check about clogging or damaging of filter. Clean or replace it, if it is
1
necessary.
CHECK THE FILTER INSIDE THE DELIVERY PAINT FILTER TF-1S: Check about clogging or damaging. Clean or
2
replace it, if it is necessary.
50 Mesh
ADVICE!
THE ICON X3 PUMP HAS BEEN DESI-
GNED TO WORK WITH PAINTS WITHOUT THE NEED
FOR LUBRICANT. HOWEVER, IN CASE OF INTENSIVE
USE, IT IS ADVISABLE TO ADD THE ANEST IWATA
LUBRICANT (94445770 - NOT INCLUDED) INTO THE
PACKING HOLDER TO EXTEND THE LIFE OF THE
GASKETS.
iCon-A233N
Airless Unit
INCREMENTAL FLUID PRESSURE
9.0MPa (90bar - 1305psi)
15.0MPa (150bar - 2175psi)
21.0MPa (210bar - 3045psi)
1
2
15