iCon-M233N
Multi Spray Unit |
8. SAFETY SYSTEMS
Several safety systems have been conceived during the ICON Units design and manufacture to safeguard the ope-
rator, in compliance with EN 12621:2010 Directive about paint.
8.1 SAFETY VALVE
A 8 BAR CALIBRATED SAFETY VALVE IS INSTALLED TO ENSURE THE
PUMP WORKING PRESSURE DOES NOT EXCEED THE LIMITS INSIDE
THE FEEDING CIRCUIT.
8.2 SAFETY BALL VALVE
WARNING
STOP
9. WORKABLE PRODUCTS
ANEST IWATA ICON PUMPS ARE CONCEIVED TO PAINT FERROUS MATERIAL IN GENERAL, WOOD AND PLASTIC.
WARNING
TO USE THE EQUIPMENT WITH SPECIAL PRODUCTS ASK FOR THE APPROVAL OF
THE MANUFACTURER.
DO NOT USE:
- ANY HALOGENATED HYDROCARBON SOLVENTS, SUCH AS TRICHLOROETHANE,
METHYLENE CHLORIDE OR SOMETHING LIKE THAT;
- ANY TOXIC PRODUCTS SUCH AS PETROL, KEROSENE OR COMBUSTIBLE GASES;
- ANY HERBICIDE OR PESTICIDE;- ANY RADIOACTIVE FLUID;
10. OPERATION
WARNING
SECURELY GROUND PUMP, SPRAY GUN, WORKPIECE AND CONTAINERS CONTAI-
NING CLENING LIQUID USED DURING FLUSHING. USE ONLY CONDUCTIVE PAILS
PLACED ON GROUNDED SITE.
Insufficient grounding can cause fire and explosion due to the static electric sparking.
12
iCon-A233N
Airless Unit
WARNING! DO NOT REMOVE THE VALVE PLASTIC
PROTECTION. ANY TAMPERING WITH COULD BE
DANGEROUS FOR THE OPERATOR AND COMPROMI-
SE THE EQUIPMENT GOOD WORKING.
IN CASE OF ANOMALIES DURING WORKING,
TURN 90° THE BALL VALVE LEVER FOR EMER-
GENCY STOP. IN THIS WAY THE AIR SUPPLY WILL
BE INTERRUPTED AND THE RESIDUAL PRESSURE
INSIDE THE PUMP WILL BE RELEASED.
iCon-M233N
Multi Spray Unit |
10.1 FLUSHING BEFORE USING
ATTENTION! THE PUMP MUST BE CLEANED BEFORE USING IT FOR THE FIRST TIME, AFTER
WORKING AND AFTER ANY COLOUR CHANGE.
1
After installation (chapt. 7), before to supply air to the pump, confirm
that the ball valve is open and the air regulator is adjusted to 0 bar.
O BAR
OPEN
ICON-M233N
ICON-A233N
3
Open the drain valve for fluid recir-
4
Set the pressure regulator up slowly, to the minimum pressure required for
culation.
the straight and alternate movement of the piston.
ICON-M233N
OPEN
5
After flushing, discharge the used deter-
6
Close the drain valve.
gent through the drain hose, lifting the
suction hose beyond the liquid level.
CLOSE
Reset the air regulator to 0 bar.
8
O BAR
OPEN
ICON-M233N
ICON-A233N
iCon-A233N
Airless Unit
2
Immerse the suction hose in the contai-
ner, containing cleaning liquid.
OPEN
ICON-A233N
7
Flow out the cleaning liquid from spray
gun.
OPEN
13