Herunterladen Inhalt Inhalt Diese Seite drucken

ECTIVE SI Serie Montage- Und Betriebsanleitung Seite 51

Vorschau ausblenden Andere Handbücher für SI Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

[
®
SINUS/SINE INVERTER – SI-/TSI-SERIES
ECTIVE
• internal temperature too high
• required output load too high
• input voltage too high or too low
Reason
12 V
risk of under-
10.8V±0.2V
voltage
total undervolt-
10.2V±0.2V
age
overvoltage
15.5V±0.2V
overheating
overload due
to powerful
consumers
short circuit of
consumers
polarity reversal
undervoltage
11V±0.2V
ECO-Mode
Please note!
Exclusion of liability
Damages caused by polarity reversal and short circuits are excluded from liability.
24 V
21.6V±0.4V
43.2V±0.8V
20.4V±0.4V
40.8V±0.8V
31.0V±0.4V
62.0V±0.8V
internal temperature >75°C
regardless of the type
regardless of the type
regardless of the type
22V±0.4V
44V±0.8V
]
48 V
Action
2x acoustic signal
+ red LED flashing 2x
every 8 sec.,
inverter still working
3x acoustic signal
+ red LED flashes 3x
every 8 sec.,
automatic shutdown
4x acoustic signal
+ red LED flashing 4x
every 8 sec.,
automatic shutdown
5x acoustic signal
+ red LED flashes 5x
every 8 sec.,
automatic shutdown
red LED flashes con-
stantly until the error
is solved and device is
switched on again
red LED flashes
constantly until error
is solved and device is
switched on again
the fuses blow
shift to mains priority
circuit
49

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis