en – Electrical connection

Window contact switch

^ A window contact switch can be
connected to the terminal a on the
control module.
When the window is closed (window
contact switch open) the cooker hood
fan cannot be switched on. The
indicator lamp for the On/Off touch
control on the cooker hood will flash.
10
The cooker hood fan can only be
switched on when the window is open
(window contact switch closed) and
sufficient air can be drawn into the
room.
The same applies to operation with an
external fan motor.
The cooker hood lighting is not affected
by this.
The connection cable between the
window contact switch and the cooker
hood must not exceed 25 m.
The window contact switch must be
tested for safety after it has been
connected.