Manual: PS-5200RGB
Set mode between Liveshow and Player
In the upper section of the Show Management, mode can be set by NetLase. To control play-
er by DMX select „NetLase starts in Player Mode". Select „Apply" take settings. Restart card to
take setting. Setting remains until selection of „NetLase starts in Live-Mode".
Note: Don't forget the switching of the setting. To control NetLase via DMX, without a PC,
player mode has to be activated. Otherwise NetLase cannot react to DMX signals. If „Live"
mode is not selected, NetLase can't react to the software of PC (e.g. Phoenix, Mamba, or HE-
Laserscan).
If all files are set in Show management, the wiring of DMX has to be selected.
11. Fault Finding:
Situation
Reason
No power for the
fuse fault
motor
power supply fault
PCB control fault
Potentiometer fault
PCB IC control fault
X, Y scanners
scanner fault
don't move; no
PCB IC control fault
patterns or jigg-
PCB control fault
ling scanners
power supply fault
scanner driver fault
No light output;
dirty mirrors
weak light output
laser diode fault
or no closed la-
PCB control fault
ser beam, other
functions are
device configuration fault
working
No control pos-
device configuration fault
sible other funk-
PCB conrol fault
tions are working
power supply fault
(e.g. laser diode
or ventilation)
PCB display fault
PCB IC control fault
It is not possible to control the device by ILDA:
page 16 / 34
/ PS-9200RGB
/ PS-18.400RGB
NL
NL
NL
Faulty Part
Fuse
+-24V
PCB Control
Potentiometer
IC
scan motor
IC
PCB Control
+-24V
scanner driver
clean with alcohol
PCB control
Check the configu-
ration (see device
operation)
see above
PCB control
+-24V
PCB display
IC
Parts Number
09-00-2001-01
16-03-0039-00
26-2A-LT12V2-00
04-03-0104-01
00-89C516RD-00
15-01-2215-00
00-89C516RD-00
26-2A-LT12V2-00
16-03-0039-00
26-2A-6800A-00
Please ask
26-2A-LT12V2-00
26-2A-LT12V2-00
16-03-0039-00
26-2A-LT228DI-00
00-STC89C54RD-00