Chronothermostat
With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week for each
day of the week in 4 independent time intervals (SET C RONO 1-2-3-4). Below are given the steps for accessing the relative menu
starting from "Home" mode.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
CHRONO
ENABLE CHRONO
SET CHRONO 1
SET CHRONO 2
SET CHRONO 3
SET CHRONO 4
CHRONO
ENABLE CHRONO
SET CHRONO 1
SET CHRONO 2
SET CHRONO 3
SET CHRONO 4
The exit key shows the CHRONO menu to set other variables related to the menu functions.
The exit key shows the CHRONO menu to set other variables related to the menu functions.
To exit the page and return to "Home" page, press the button repeatedly.
Air - pellet set
The setting of the PELLET-FLUSSO mixture allows to adjust the combustion by varying the quantity of pellets loaded in the brazier and/
or the quantity of air. In fact, by its nature, pellets vary in grain size and composition: even bags of pellets of the same brand can have
different characteristics.
If combustion is not optimal, vary the flow parameter to adjust the combustion air. If air regulation alone is not sufficient, it may also be
necessary to modify the pellet parameter.
Combustion regulation is an operation that requires a lot of experience. We recommend that you contact an Authorised
Service Centre to calibrate the stove appropriately.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
Use the UP and DOWN
keys to change the % pellet
value.
To exit the screen and return to the home screen, press the key repeatedly.
Use and maintenance manual Rc-Rv 120 Touch steel
Press the key
"confirm"
to access the
USER page
Press the key
"confirm"
to access the
USER page
% Flow
Press the CONFIRM button
to confirm the value and
go to the item % change
flow.
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
ENABLE CHRONO
Press the key
"enter" at the end of the
setting, from the following
CHRONO page
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
% Flow
Use the UP and DOWN buttons to change the
flow % value. Press the CONFIRM button to
change to the item % pellets.
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
Press the key
several times
to quickly switch to
CRONO-THERMOSTAT.
ENABLE CHRONO
Ignition time
VENTILATION POW.
Shutdown time
Day of the week when the
program is active
Program number "chrono"
Press the increase/decrease keys
Power setting
Setting the room temperatures
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
Press the selection
Press the key
keys to navigate the
several times
menu screens.
to quickly switch to
USER.
Stove STATUS.
confirm the value and
Rev.0 18/05/2020
Pag.36
USER
"increase/decrease"
to change the ventilation.
Select SET AIR-PELLET
and press the CONFIRM
button.
Inhaltsverzeichnis