Failed ignition
In models without a self-cleaning brazier, check that the brazier is empty and clean.
The brazier could be very hot: danger of burns!
Never empty the brazier inside the hopper.
Setting operating temperature and power:
Set the two values following the indications given in the chapter "Description of thr display"
Turning the device on
Keep the key ON/OFF pressed for a few seconds to turn on the stove.
Operating phases of the appliance
Sequence of ignition phases
SWITCH-ON- initial pellet loading phase;
FLAME PRESENT - flame stabilization phase and reduction of combustible inside the brazier;
WORK - operation phase described in the dedicated chapter;
Modulation
During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove switches to MODULATION
mode in which fuel consumption is minimum.
If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to
the appropriate connector on the rear side of the stove; and you will have to activate the reading in "SETTINGS - ENABLE
THERMOSTAT." On display appears the writing TON / TOFF based on thermostat request.
Connect an external thermostat with a simple dry contact, therefore, not powered, moreover, we reccomend you use a
thermostat with a minimum offset of 3°C if you ntend to use the comfort clima function.
Description of menu functions
Press the key to access the MENU page
The TECHNICAL and PRODUCER menus are password protected. Changing parameters within these menus could
compromise the operation and safety of the stove. In this case the warranty will be invalidated.
Use and maintenance manual Rc-Rv 120 Touch steel
MENU
USER
MANUFACTURER
ENGINEER
Rev.0 18/05/2020
Pag.35