PPROCEDURES FOR USE
If the chimney catches fire you must call the fire brigade immediately.
Checks prior to start-up
You have read and perfectly understood the contents of this instructions manual.
Before lighting the stove, you must ensure that:
•
the combustion chamber is clean;
•
the fire door and ash drawer seals are functioning properly;
•
the electrical plug is connected correctly;
•
all items that could burn (instructions, various adhesive labels) have been removed;
•
the brazier, if removable, is correctly positioned in its housing.
During the first hours of use the paints used for the stove finish may release an unpleasant odour. You might also smell the
typical odour of metal parts subject to high temperatures. Make sure sufficient air circulation is guaranteed in the room. These
unavoidable inconveniences will disappear after the first hours of operation. To reduce your discomfort to a minimum, keep
the stove on for a few hours on low power and in the beginning, do not overload it, avoiding intense heating-cooling cycles
At the initial start-up, the paint finishes drying and hardens. Accordingly, to avoid ruining it, we advise you not to touch the
stove's painted surfaces at this time.
Feed screw loading
Before starting the stove for the first time, whenever the stove is in alarm "06 - Pellets finished", and in any case whenever the hopper
has emptied completely, the initial feed screw loading is required. This phase involves filling the pellet loading system so that when
the system is started, it is ready to load the pellets into the brazier.
MENU
USER
MANUFACTURER
ENGINEER
Press the "menu access"
button to access the
MENU screen.
In the event that the feed screw operations are not carried out, there may be stove ignition failures.
After loading the auger and before lighting the stove, always remember to empty the brazier and check that the brazier is
clean. Never empty the brazier inside the hopper.
In models with self-cleaning brazier it is not necessary to remove the pellets in the brazier: the pellets loaded are sufficient
for subsequent ignition.
Switching the appliance on and o
From the " ome" screen, it is possible to switch the stove on and o by keeping the ON / OFF button pressed on the device for a few
seconds. An acoustic signal will warn you that the appliance has switched on or o . In case it is not possible using your handheld you
can switch the appliance on / o using the appropriate button on the electronic board.
The brazier is mechanically cleaned before each ignition, except after the initial screw feed and in case of re-ignition after
an FAILED IGNITION alarm
Use and maintenance manual Rc-Rv 120 Touch steel
Press the "confirm"
button to access the
USER screen
USER
SCREW FEEDING
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
Press the "confirm"
button to activate feed
screw rotation
Rev.0 18/05/2020
Pag.34