Herunterladen Inhalt Inhalt Diese Seite drucken

InfraWave RR-130 PENTAGON Bedienungsanweisung Seite 31

Vorschau ausblenden Andere Handbücher für RR-130 PENTAGON:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

General
If the infrared cabin is connected to the mains the following message appears on the display:
Every time a key is pressed, a small beep will sound. When a function is not available or
when a value cannot be adjusted further, the beep will sound "louder". The cabin light and the floor
heating can always be switched on or off.
Infrared session
An infrared session starts by pressing the Timer key.
The following message displays:
> Time: 23 min <
F :70%
The infrared heaters, the floor heating and the cabin light switch on immediately.
When the session expires, the unit automatically returns to stand by mode. The session can
end manually by pressing the Timer key for 2 seconds.
The arrows (> or <) in the display message indicate which value can be changed by using the
up and down keys, i.e. the session time in this case. This is the default indication during the session.
During a session the display shows the remaining time. The last minute is displayed in seconds.
Ш When the Front Zone key is pressed, the signs shift to the Front Zone settings. The intensity
of the Front Zone is adjusted through the up and down keys.
Ш When the Back Zone key is pressed, the signs shift to the Back Zone settings. The intensity
of the Back Zone is adjusted through the up and down keys.
Ш When the Leg Zone key is pressed, the red Led is on, which means that the Leg Zone is
turned ON,
– Turn ON of the Leg Zone
Ш
When the Floor heating key is pressed, the red Led is on, which means that the Floor
heating is turned ON
– Turn ON of the
Floor heating
Cabin light
During an infrared session and in stand-by mode the cabin light can be switched on and off
By means of the Light key.
At the end of an infrared session, the cabin light is automatically switched on for two minutes;
afterwards the light is manually switched off.
STANDBY
R :70%
,
– Turn OFF of Leg Zone
– Turn OFF of the
Floor heating
31
EN

Werbung