Malfunction remedy
Malfunction
Pump does not start
Pump does not
transport fluid
Insufficient delivered
quantity
Pump switches off af-
ter operating briefly
Possible cause
No mains voltage
Excessively soiled water
The impeller unit is blocked
Impeller unit is running slug-
gishly
Excessive loss in the pipes due
to friction
Excessively soiled water
Water temperature too high
Ambient temperature too high
The impeller unit is blocked
Pump has run dry.
Remedy
• Check the mains voltage.
• Check supply lines.
• Switch on the pump.
Clean the pump. The pump automat-
ically switches on again once the mo-
tor has cooled down.
Disconnect the power supply and re-
move obstacle. Then switch the
pump on again.
Clean the impeller unit
• Select a larger pipe diameter.
• Reduce pipe length to the neces-
sary minimum.
• Avoid unnecessary bends and con-
nection elements.
Clean the pump. The pump automat-
ically switches on again once the mo-
tor has cooled down.
Note maximum water temperature
of +35°C. The pump automatically
switches on again once the motor
has cooled down.
Adhere to the maximum permissible
ambient temperature. The pump au-
tomatically switches on again once
the motor has cooled down.
Disconnect the power supply and re-
move obstacle. Then switch the
pump on again.
Flood the pump. Fully submerge the
pump for operation in the pond.
EN