1. MOUNTINg OF FlOOR SENSOR
Place the floor sensor in an approved non conductive installation pipe in
accordance with EN 61386-1, which is embedded in the floor. The pipe end is
sealed and placed in the concrete layer as close as possible to the surface. The
installation pipe must be centred between the heating cable loops. sensor cable
can be extended by up to 100 m by means of a separate cable.
2. MOUNTINg OF ThERMOSTAT WITh bUIlT-IN SENSOR
The room sensor is used for comfort temperature regulation in rooms. The
thermostat should be mounted on the wall approx. 1.5 m above the floor in such
a way as to allow free air circulation around it. Draughts and direct sunlight or
other heat sources must be avoided.
3. OPENINg ThE ThERMOSTAT
Slide the power button down to Off "0" (Pic. 1).
1.
2.
Release the front cover ONLY by inserting a small screwdriver into the slot
at the centre of the bottom side of the front cover to press and hold the
catch securing the front cover.
3.
Then carefully pull the front cover away, initially from the lower part of the
thermostat, then from the upper part of the thermostat.
4. CONNECTIONS
Connect the wires in accordance with the diagram. The wires must be connected
as follows (Pic. 2):
4