O P E R A T I N G I N S T R U C T I O N S
USB microscope camera
500x enlargement
Item no. 19 13 89
Use in accordance with manufacturer's instructions
The product is a camera designed to transfer the recorded image via a USB port to a PC. Thanks to the
integrated lens, particularly small objects/surfaces can be magnifi ed and imaged. The power is supplied via
a USB port.
This product complies with the applicable National and European requirements. All names of companies and
products are the trademarks of the respective owners. All rights reserved.
Package Contents
• Microscope camera
• Table stand
• CD with driver/software
• Operating Instructions
Safety Instructions
The warranty will be void in the event of damage caused by failure to observe these safety
instructions! We do not assume any liability for any consequential damage!
We do not assume any liability for material and personal damage caused by improper use
or non-compliance with the safety instructions. In such cases the warranty will be null
and void.
• The unauthorised conversion and/or modifi cation of the product is not permissible for reasons
of safety and regulation (CE).
• The product should only be used in dry indoor areas, it must not be exposed to damp or wet!
• The product is not a toy and should be kept out of the reach of children.
• Caution, LED light:
Do not look directly into the LED light!
Do not look into the beam directly or with optical instruments!
• Do not leave packing materials unattended. They may become dangerous playthings for chil-
dren.
• Handle the product with care; it can be damaged by impacts, blows, or accidental drops, even
from a low height.
Driver/Software Installation
Operating system and application software are subject to permanent change by updates. There-
fore not all contingencies can be pointed out in these operating instructions, but solely the basic
software installation.
• Start your operating system. Place the CD included in the delivery in an appropriate drive on your compu-
ter.
• The software now starts automatically and you can install the software. If the CD does not start automati-
cally, you must start the installation program on the CD manually (main directory on the CD, e.g. "Autorun.
exe" etc.). Follow all of the software's instructions. The serial code required by a dialogue window can be
found on the CD cover.
On the desktop of your computer a new icon is created. Now connect the microscopic camera to a free
USB2.0 port on your computer. The operating system recognises the new hardware and completes the
driver installation. Please read the manufacturer's information that can be found on the CD.
• Start the software by double clicking on the newly created icon.
• A new window is opened. Now the program and the micro camera are ready for operation.
• To operate the software different symbols will be shown:
1
3
5
2
4
1 Resolution settings
3 Video recording
5 Full screen
7 "Freeze" image
9 Settings
www.conrad.com
7
9
8
6
10
2 Create photo
4 Delete fi les
6 Date and time
8 Measurement grid
10 "Help fi le"
Controls
1 Objective (with LED illumination)
2 Adjustment dial
Version 11/11
3 Locking bolt
4 Stand
5 Rotary knob (LED brightness)
Operation
• By means of the rotary knob in the connection cable (5) the LED illumination in the front of the lens can be
turned off or the brightness can be adjusted steplessly.
• Move the lens (1) of the microscope camera as close as possible to the desired object (e. g. place the front
on a newspaper).
• Adjust the picture until it the image is sharp by using the adjustment dial (2).
Do not overwind the adjustment dial. Turn the adjustment wheel slowly, so that you can focus the
picture accurately.
With refl ective surfaces or objects, the LED light can result in overexposed pictures or refl ec-
tions.
• Turn the microscope camera or the object to be viewed until the picture is aligned as desired.
Make sure no objects touch the lens as they might damage it. Do not touch the optics (the lens
will get dirty).
• The microscope camera can be fi xed at a given position using the table stand included in the delivery; the
locking bolt (3) fi xes the position of the table stand.
Handling
Never use the product immediately after it has been taken from a cold room to a warm one. The
condensation that forms might destroy your unit.
Allow the device to reach room temperature before switching it on. This may take several hours.
The housing must not be opened! Any maintenance or repair work may only be carried out by
authorised personnel.
The following unfavourable conditions are to be avoided when installing or transporting the product:
- Excessive humidity or damp
- Extreme cold or heat
- Dust or fl ammable gases, fumes or solvents
- Strong vibrations
- Strong magnetic fi elds such as those found in the vicinity of machinery or loudspeakers
When setting up/using the product, ensure that the cables are not bent, over-tightened or
squeezed.
Cleaning
Check the lens of the microscope camera occasionally, clean it of dust and dirt. Use an appropriate lens
cleaning system, e. g. a clean, soft brush. Do not press too hard on the optics/mechanics of the camera,
since they may be damaged. Furthermore, you may cause scratch marks on the lens.
Disposal
Dispose of an unserviceable product in accordance with the relevant statutory regulations.
Technical Data
Sensor ........................................CMOS, 1600 x 1200 pixels (2 MP)
Resolution image ..... .................. max. 2560 x 2048 pixels (only via software)
Resolution video ......................... max. 640 x 480 pixels
Image refresh rate ..................... 30 images per second
USB connection . .........................USB2.0
Operating voltage .......................5V= (via USB)
Illumination .................................4 white LEDs
Magnifi cation ..............................90x to max. 500x at 20" (51 cm) monitor
Area of focusing ..........................up to 10mm
Dimensions (Ø x L) .....................approx. 37 x 140 mm
2
1
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2011 by Conrad Electronic SE.
5
3
4

Werbung

loading