Validate the program; the validated days are then highlighted in
green (on this example: Monday and Tuesday).
The days that are not programmed are displayed in red.
c- Edit: To view and modify an existing program
d- Information: to view the current program
P1: morning, evening & weekend.
P2: morning, midday, evening & weekend.
P3: day & weekend.
P4: evening & weekend.
P5: morning, evening (bathroom).
ON/OFF DEVICES MANAGEMENT
Press on
in the main screen and on
1. Device type choice (heating/cooling, On/Off). These buttons
are only displayed if one device type is installed in the room
(colored if active).
2. Room changing.
3. Information about the device.
4. Indicates both the number of the current device / number of
devices in the room.
5. Indicates the ON/OFF status. A press on it switches the
status of the device.
6. General management for all the ON/OFF devices in the
room.
7. Current room.
8. Quick access to the desired room.
9. Only displayed if the number of devices is upper than 1; used
to select the devices in the room.
10. Long press to switch between auto mode and normal mode
(colored if active).
11. Displayed only if the device is in Auto mode, press to
access and edit the device program.
12. Only displayed if the screen is locked.
PAIRING
Create the room if it doesn't exist
House creation
Radio pairing
- Choose the device type (heating, ON/OFF, external probe or
circuit)
- Choose the room
Note: The master must be the first paired device.
- Put the device in pairing mode (refer to device leaflet)
- Start the pairing on the Central
- Follow the instructions given by the Central (check on the
device that the pairing is successful, refer to the device
leaflet)
- Note: Automatic pairing time in case of RF communication
loss: 10s.
- When you have finished pairing all devices and installed all
devices in their final location, you have to make sure that the
range allows good communication between devices. Please
modify the heating/cooling mode or the setpoint on the
central and make sure that the information is received by the
thermostat and the receiver.
Check the successful installation
-
- You will have warning in home menu
communications. These errors should desappiers in 10
minutes maximum. If not, check devices who still in rf errors
put them in another place and repeat the procedure.
Hydraulic systems
If your installation has hydraulic elements, you may have to
drive pumps or boilers. With Touch E3 you can drive directly up
to 4 hydraulic circuits. And for each of those circuits, an RF
remote device can be linked. It works easily: if at least one
element of the circuit has a heating/cooling demand, the
element will drive the circuit and make the water flows.
First step: define on which circuit an element belongs to
With the plan of your installation, define which elements are on
"circuit 1". Once it is done, on the Touch E3, configure all
elements (heating/cooling device) that are on circuit 1.
To do this, in the main screen press
on circuit 1, then press
and press
5 seconds. Now you have entered the
configuration menu of the device.
Choose menu "HC", now you have two option Electrical or
Hydraulic, select Hyraulic and then press on button
you can select the circuit, that the device will act on.
Proceed like this for every heating/cooling device of this circuit.
Once all elements of circuit 1 are set, do the same for the other
hydraulic circuits.
Second step: control the circuits
For each circuit, you can link an element to drive the
pump/boiler of the circuit. This can be done for example by a
single zone receiver with 2 relais.
From the main screen, press
box, choose "Radio pairing", then "Circuit". Select the number of
the circuit, put the element to link (single zone H&C RF) in link
mode, then start process by pressing
Do the same for the other circuit, if you have more.
Heat and Cool installations
If your installation can make cooling, then you can switch either
from Heat to Cool manually or automatically:
- If you have a Pac Module in your installation set as
"Master" (refer to Manual instruction of the device) then all
is automatic you don't have to do anything
6
for rf errors
, enter a zone that is
and select one device of circuit 1
. Now
then press