13.1
DIP1 - Configuration setting
Set to ON for configuration with a computer and NEAT
programmer software.
• If DIP1 is ON then DIP2 to DIP8 are ignored.
13.2
DIP2 - Power save mode
Sending alarms consumes battery power and in
order to save battery PIR II can be set to either of
two power modes, Power Save (DIP2 = ON) or Static
(DIP2 = OFF).
• DIP2 is ignored if DIP3 is ON.

13.2.1 Power save

In Power Save PIR II sends the first alarm (Tx)
where-after there must be NO movement detection
(M) for 60 seconds before PIR II will send a new
detection alarm (Tx).
Any movement detection (M) within the 60 second
time frame will be ignored and the timer is reset to
60 seconds.
M
Tx
Picture 11. Movement detection (M) and transmission (Tx) in
Power Save Mode.
PIR II User manual - NE41 19003-00 v1.2
60 s