3.
Installation
Install and connect the receiver respecting the following guidelines to guarantee an optimal reception:
-
The receiver must be mounted at a minimum distance of 50cm of all others electrical or wireless materials
like GSM, Wi-Fi router.
-
Wiring work related to the receiver must be carried out only when de-energized
-
Connect your receiver to the power supply.
Depending on your installation, an order of pairing must be respected to ensure a correct RF signal transmission.
Installation 1: Receiver + RF thermostat
1.
Switch on the receiver.
2.
Press the RF button during 5 sec to switch to RF Init.
3.
The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration
mode waiting for a thermostat configuration address.
4.
Please refer to the thermostat leaflet for enter the thermostat in "RF Init" mode.
5.
The receiver RF LED must be switched OFF and the thermostat should exit the RF init mode to indicate correct
paring between both elements.
You can pair several receivers to the same RF thermostats
Note for installations 2, 3 and 4: You can pair several receivers. Pay attention! Before linking a new receiver with the Central
unit, you have to reset the receiver imperatively.
Installation 2: Receiver + RF Thermostat + RF Central unit for heating regulation
1.
First step is to pair the RF thermostat to the Central unit
2.
Press the RF button on the receiver during 5sec.
3.
The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration
mode waiting for a central configuration address.
4.
Please refer to the leaflet of the Central unit for more explanation about the pairing mode "RF Init". You must pair
the Receiver as a heating device in the Central unit
5.
The RF LED on the receiver will switch OFF and the Central will show a message to indicate correct pairing
between both elements.
.
You can pair several receivers in the same room.
Installation 3: Receiver + RF Central unit for ON/OFF or light control
1.
Press the RF Button 5sec to switch the Receiver in RF Init mode .
2.
The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration
mode waiting for a central configuration address.
3.
Please refer to the leaflet of the Central unit for more explanation about the pairing mode "RF Init". You must pair
the Receiver as an ON/OFF plug or a light in the Central unit
4.
The RF LED on the receiver will switch OFF and the Central will show a message to indicate correct pairing
between both elements.
You can pair several receivers in the same room. Receiver will work in Timer mode; you have the possibility to create a
weekly program for ON/OFF period.
Installation 4: Receiver + RF Central unit for heating regulation. Only valid for the Flush receiver with floor sensor
1.
Press the RF Button 5sec to switch the Receiver in RF Init mode.
2.
The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration
mode waiting for a central configuration address.
3.
Please refer to the leaflet of the Central unit for more explanation about the pairing mode "RF Init". You must pair
the Receiver as a heating device in the Central
4.
The RF LED on the receiver will switch OFF and the Central will show a message to indicate correct pairing
between both elements.
Remarks:
-
In case of a thermostat in RF Alarm, the receiver (Connect 1M RF Web, Plug, Connect 1M RF Web, UP or
Connect 1M RF Web, LC) will follow 20% cycle of heating to prevent the installation against frost. (The receiver
will stay in OFF mode if it was in OFF before the loss of RF communication).
-
Plug receiver, Flush receiver, Wall receiver: The leds are switched off between 8pm and 8am when using a BT-
DP02 RF
-