300
Anhang
Tabelle 162: MODBUS-Register
Register-
adresse
0x0630 to
0x064F
Dual-Ring Information
0x0700
0x0701
0x0704
0x0705
0x0706
0x0707
0x070a
Datentyp Dar-
Beschreibung
stellung
1 word
Hex
Ring Port:
0x0000: No
0x0001: Yes
1 word
Hex
Dual- Ring State:
0x0000: Disabled.
0x0001: Enabled.
3 word
Hex
Xpress-ring MAC for Dual-Ring:
Ex: MAC=00:01:02:03:04:05
Word 0, high byte=0x00.
Word 0, low byte=0x01.
Word 1, high byte=0x02.
Word 1, low byte=0x03.
Word 2, high byte=0x04.
Word 2, low byte=0x05.
1 word
Hex
Xpress-ring Role for Dual-Ring:
0x0000 : Forwarder
0x0001 : Arbiter
2 word
Hex
Xpress-ring Current status for Dual-Ring
Port-1 – (Primary Port)
High byte – Port No.
0x01~ 0x0a: Port 1~Port 10
Low byte – Port Status
0x00 : No connection
0x01 : Forwarding
0x02 : Blocking
Ex: 0x0501– Port 5 Forwarding
0x0b02 – Port 12 Blocking
Port-2 – (Secondary Port)
High byte – Port No.
0x01~ 0x0a: Port 1~Port 10
Low byte – Port Status
0x00 : No connection
0x01 : Forwarding
0x02 : Blocking
Ex: 0x0501– Port 5 Forwarding
0x0b02 – Port 12 Blocking
3 word
Hex
Sub-Ring Master Bridge MAC :
Ex: MAC=00:01:02:03:04:05
Word 0, high byte=0x00.
Word 0, low byte=0x01.
Word 1, high byte=0x02.
Word 1, low byte=0x03.
Word 2, high byte=0x04.
Word 2, low byte=0x05.
1 word
Hex
Jet Ring Total Nodes for Sub-Ring.
Ex: When total nodes is 255(0xff).
Word 0, high byte=0x00.
Word 0, low byte=0xff.
WAGO-ETHERNET-Zubehör 852
852-1305 8/4-Port 100Base-T/1000Base-SX/LX
Handbuch
Version 1.1.1

Werbung

loading