Thermostat status (cool mode only)
A snowfl ake symbol will be lit whenever the thermostat is calling
for cooling. If this is seen to fl ash, the thermostat output is
delayed for a short period to prevent compressor damage.
Thermostat standby
To place the thermostat into standby (off ), press the V arrow
twice to enter the temperature setting mode. When in heating
mode press and hold the V arrow until the set temperature
disappears and the standby symbol appears. In cooling mode
press and hold the Λ arrow until the standby symbol appears.
When in standby the thermostat will have no control of the
heating or cooling system.
To exit standby press and hold the Λ arrow (V arrow in cooling
mode) until the required set temperature is fl ashing on the
display.