Herunterladen Inhalt Inhalt Diese Seite drucken

Stocker 303 Benutzerhandbuch Seite 53

Schubkarrenpumpe mit batterie 80 l und 100 l
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9
The pump should be kept in a dry place away from children. Do not keep it unused for too long
as it may cause damages to the battery. The pump should not be stored at temperatures below
15°C.
104
Art. 303 / Art. 304
Wheelbarrow battery pump 80 L and 100 L
Storage
Art. 303 / Art. 304
Wheelbarrow battery pump 80 L and 100 L
Troubleshooting
Problem
Causes
1. A fuse has melted
2. Battery out of power
3. Power switch has been
The motor fails to run after
damaged
being powered on
4. Power wires
come off
5. Motor damaged
Abnormal sounds with the
1. The fastening screws of
motor in operation
pump are loosen
1. The inlet and outlet pipes of
Leakage occurs to the
the pump are loosen or broken
underside of the base
2. Caps or seals are damaged
1. Low pressure
2. The holes inside the
sprayer are clogged
Poor atomization results
3. The joints of the pipes lose
4. The battery is low
5. The tube is bent
For further information about the product, please contact info@stockergarden.com.
Sign up to our newsletter and keep up to date with our latest news info@stockergarden.com
10
Solutions
1. Replace it
2. Recharge
3. Replace the
switch
4. Disassemble the base to
reconnect the wires
5. Replace the motor
1. Tighten the screws
1. Disassemble the base to
tighten the pipe clam; repair it
2. If necessary, replace the
caps and gaskets
1. Increase the pressure
2. Remove
impurities
3. Tighten the joints
4. Recharge the battery
5. Check that the tube is
not bent