ENGLISH
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts
remain
on
machine.
Compressor does not run:
•
No mains voltage.
− Check cables, plug, outlet and
mains fuse.
•
Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
•
Compressor
was
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
9. Technical Specifications
Suction capacity
Free air delivery (volume flow rate)
Filling rate
Working pressure (compression end pressure)
Pressure vessel volume
Pump model
No. of cylinders
Motor speed
Motor capacity
Supply voltage (50 Hz)
Rated current
Fuse protection min.
Degree of protection
Max. overall cable length when using extension cables:
2
– at 3 x 1.0 mm
lead cross section
2
– at 3 x 1.5 mm
lead cross section
2
– at 3 x 2.5 mm
lead cross section
Dimensions length x width x height
Weight
Sound pressure level at 1 m max.
10
•
Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
− Remove cause for overheating
and allow to cool down for
or
in
the
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
•
Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
•
Pressure regulator not opened wide
enough.
− Open pressure regulator more.
stopped
by
•
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
A
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
8. Environmental Protection
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
Basic 240
l/min
220
l/min
105
l/min
110
bar
8
l
24
F 205
1
-1
min
2850
kW
1.1
V
230
A
6.2
A
10 (time-lag)
IP 20
m
10
m
25
m
50
mm
615 x 325 x 630
kg
21.5
dB (A)
85 ± 3
Danger!
Repairs to power tools must be
Basic 240 (GB 110V)
220
105
110
8
24
F 205
1
2750
1.35
110
14.0
IP 20
615 x 325 x 630
21.5
85 ± 3