Cleaning Airless spray gun G 12

8.4 Cleaning Airless spray gun G 12
– Rinse Airless spray gun with an appropriate
cleaning agent.
– Clean tip thoroughly with appropriate cleaning
agent so that no coating material residue re-
mains.
– Thoroughly clean the outside of the Airless
spray gun.

9. Remedy in case of disturbance

Type of malfunction
Unit does not start
Unit does not exert
suction
36
Downloaded from
www.Manualslib.com
1
2
3
4
5
Possible cause
No voltage.
Fuse protection has reacted. For example
an agitator is connected to the socket on
the unit. This agitator has not been switch-
ed off before switching on the unit Super
Finish 21 or 23.
The unit switches off automatically in case
of overloading.
The unit does not switch on again inde-
pendently.
Unit with suction system:
Filter extends beyond the liquid level and
sucks in air.
Suction filter congested.
Suction pipe not tightened, i.e. the unit
sucks in ancillary air.
Device with upper hopper:
Filter disk congested.
manuals search engine
g
g
Intake filter in Airless spray gun
Dismounting (fig. 18)
1. Pull protective guard (1) forward vigorously.
2. Screw grip (2) out of the gun housing. Remove
intake filter (3).
3. Intake filter congested or defective – replace.
Mounting
1. Place intake filter (3) with the long cone into
the gun housing.
2. Screw in grip (2) into the gun housing and
tighten.
3. Slot in protective guard (1).
rm
G e
in
d e
M a
2
G 1
m ax
.
ps
00
r
39
0 ba
27
1
Measure for elimination of malfunction
Check voltage supply
First switch on the unit Super finish 21 or
23 and then, for example, the connected
agitator.
Again after 2 - 3 minutes, switch unit on
again.
Refill coating material.
Clean or replace suction filter.
Clean and tighten connections.
Clean or replace filter disk.
Remedy in case of disturbance