Herunterladen Inhalt Inhalt Diese Seite drucken

Filter Disposal - Scott Safety TORNADO T/POWER SPF Gebrauchs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
The table below shows Device Cassification and Protection Factor
European Device Classification
TH2
TH3
TM2
TM3
* According to EN 529 : 2005
Note P R SL filters are suitable for all types of particulate hazards including dust, mist and fume of all types,
radioactive dusts, bacteria and viruses.
Please contact Customer Services at Scott Safety for more detailed information on filter selection, appropriate
maximum use concentration levels and relevant local legislation.
The
filters are available for use with Tornado T/Power SPF :
following
Code
TH1/TH2/TH3/TM2/TM3 P R SL
PF251/2
(Particulate)
TH1/TH2/TH3/TM2/TM3 P R SL
PF251/SUPER
(Particulate)

FILTER DISPOSAL

Filters must be disposed of in accordance with local waste treatment regulations. Particulate filters constitute
normal waste (can be, for example, incinerated). But they are considered hazardous waste if hazardous
substances have been filtered through them.
FITTING
Filter to PAPR
See Page 2 - Fig 1.A / 1.B.
Screw the filter firmly home until the tab on the base of the filter passes over the protrusion or 1st Mark on the
blower body or filter adaptor (shown as 1 in Fig 1.B). Continue until the filter is finger tight. DO NOT OVER-
TIGHTEN. DO NOT allow the tab to pass the 2nd Mark (shown as 2 in Fig 1.B).
Hose to PAPR
See Page 2 - Fig 2.
Battery to PAPR
See Page 2 - Fig 3.
DONNING
See Page 2 - Fig 4.A / 4.B.
For headtop donning instructions see headtop user manual.
IN USE
PAPR - TURNING ON & OFF
With the unit mounted on your waist you can pull the unit around to your side to view the display, the view you
get is shown below:
A
B
Power On
Before switching on ensure:
Ensure battery is not damaged, and has been fully charged.
Battery Pack is fitted and secure.
Assigned* Protection Factor
Filter Type
C
D
20
40
20
40
Colour Code
Solid and liquid particulates, including: dusts, mist,
White
fumes, fibres, bacteria and virus
As PF251/2. Longer lasting, high capacity
White
particulate filter
Key Meaning
A
Power button
B
Power icon
C
Low flow rate LED
D
Low battery LED
7
Nominal Protection Factor
50
500
200
2000
Application
Tornado T/Power SPF Iss A

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis