Herunterladen Inhalt Inhalt Diese Seite drucken

Overview: Configuration - Daikin Altherma 3 H HT W Installationsanleitung

Vorschau ausblenden Andere Handbücher für Altherma 3 H HT W:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
A
A
B
C
B
C
3 Fix the cable with cable ties to the cable tie mountings.
NOTICE
Make sure to select and install the safety thermostat
according to the applicable legislation.
In any case, to prevent unnecessary tripping of the safety
thermostat, we recommend the following:
▪ The safety thermostat is automatically resettable.
▪ The safety thermostat has a maximum temperature
variation rate of 2°C/min.
▪ There is a minimum distance of 2 m between the safety
thermostat and the motorized 3‑way valve delivered
with the domestic hot water tank.
INFORMATION
ALWAYS configure the safety thermostat after it is
installed. Without configuration, the unit will ignore the
safety thermostat contact.
INFORMATION
The preferential kWh rate power supply contact is
connected to the same terminals (X5M/9+10) as the safety
thermostat.
Thus,
the
preferential kWh rate power supply OR a safety
thermostat.
ETBH/X16DF6V+9W
Daikin Altherma 3 H HT W
4P586453-1C – 2020.10
10
9
Q4L
system
can
have
EITHER
6
Configuration
INFORMATION
Cooling is only applicable in case of:
▪ Reversible models
▪ Heating only models + conversion kit (EKHBCONV)
6.1

Overview: Configuration

This chapter describes what you have to do and know to configure
the system after it is installed.
NOTICE
This chapter explains only the basic configuration. For
more detailed explanation and background information,
see the installer reference guide.
Why
If you do NOT configure the system correctly, it might NOT work as
expected. The configuration influences the following:
▪ The calculations of the software
▪ What you can see on and do with the user interface
How
You can configure the system via the user interface.
▪ First time – Configuration wizard. When you turn ON the user
interface for the first time (via the unit), the configuration wizard
starts to help you configure the system.
▪ Restart the configuration wizard. If the system is already
configured, you can restart the configuration wizard. To restart the
configuration
wizard,
go
Configuration wizard. To access Installer settings, see
commands" [ 4  18].
"To access the most used
▪ Afterwards. If necessary, you can make changes to the
configuration in the menu structure or the overview settings.
INFORMATION
When the configuration wizard is finished, the user
interface will show an overview screen and request to
confirm. When confirmed, the system will restart and the
home screen will be displayed.
Accessing settings – Legend for tables
You can access the installer settings using two different methods.
However, NOT all settings are accessible via both methods. If so,
the corresponding table columns in this chapter are set to N/A (not
applicable).
Method
Accessing settings via the breadcrumb in the
home menu screen or the menu structure.
To enable breadcrumbs, press the
in the home screen.
Accessing settings via the code in the
overview field settings.
See also:
settings" [ 4  18]
"To access the installer
"6.5 Menu structure: Overview installer
6 Configuration
to
Installer
settings
Column in tables
#
For example: [2.9]
button
Code
For example: [C-07]
settings" [ 4  26]
Installation manual
17
>

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Etbh16df6vEtbh16df9wEtbx16df6vEtbx16df9w

Inhaltsverzeichnis