3. Mounting preparation
For power supply of the IoT Gateway Outdoor you need
the PoE Injector incl. power cord.
A 5m network cable incl. RJ45 connectors and PG gland
is already connected to the gateway (see ill. 6).
If the cable length is not sufficient or a network cable
is already present, you can cut the mounted network
cable, pull off the PG gland and use the supplied RJ45
connectors to crimp your network cable. In this case,
special tools are needed. It is also recommended to
perform a function test of the cable after crimping.
4. Installation
4.1. Pole mounting
Attach the mounting bracket incl. mounted housing to
the desired pole using the u-shaped mounting hard-
ware. To do this, you must attach the spacer sleeves to
the mounting hardware and then tighten each side with
a washer, spring washer and nut.
Check that the gateway is stably attached to the pole.
4.2. Wall mounting
Check whether there are any lines running at the
selected mounting location.
For wall mounting, use the 4 slotted holes (2 at the top,
2 at the bottom) on the mounting bracket.
Mark drilling holes on the wall according to the hole
spacing and use a spirit level. Note the length of the
network cable (range to the PoE Injector).
Drill holes, fix dowels and screws (not included, e.g. M8)
in the holes.
Attach mounting bracket incl. housing to the wall. Make
sure that the correct side of the mounting bracket is
facing up. Please refer to ill. 3.
60
ill. 2
5. Electrical connection
5.1. PoE injector
Connect the power cord to the PoE Injecor.
Then connect the network cable of the gateway to the
"PoE" port of the PoE Injector.
If local network access should be used, the correspond-
ing cable is to be connected to the "Data" port. If local
network access is to be used, the corresponding cable
must be connected to the "Data" port.
5.2. Antennas
The following illustration shows the usual arrangement
and mounting positions of the antennas.
Note: The specifications of the LoRaWAN antennas differ
from the LTE broadband antenna. Please take care not
to mix up the antennas or connections!
Attach the antennas and make sure to tighten the lock
nuts accordingly (wrench size SW19).
Now connect the antennas with the antenna cables and
115
10
the connectors on the housing using the following
connection layout.
8
115
197
ill. 3
ill. 4
ill. 5
Connector Layout
LoRa 2
POE
LoRa 1
LTE main
ill. 6
LTE div.
8