Installation
Installation instructions for Solenoid valve 30012 (accessory)
The solenoid valve (30012) prevents the tank from emptying in case the fuel line
breaks.
The fuel fi lter should be installed before the solenoid valve.
In a fuel hose with a T branch, the solenoid valve must function with both connect-
ed devices. Connect the solenoid valve to a relay group (accessory) and the relay
group to the devices.
Two devices can also be installed to the fuel system by connecting both devices
through their own tank connections and solenoid valves. This way the relay group
is not required.
Solenoid valve
Our recommendations in the fol-
lowing
installation scenarios:
1. Fuel level is below the heater/stove.
Picture 1.
Recommended installation scenario
No special accessories required
2. Fuel level may temporarily rise above
the heater/stove (e.g. in the fuel tank fi ller
pipe or when the boat tilts). Picture 2.
No special accessories required
3. Fuel level is above the heater/stove.
Picture 3.
Non-recommended installation scenario
Solenoid valve (30012) must be in-
stalled in the fuel hose near the tank
If the fuel level in the tank is above the device, a solenoid valve 30012
must be installed in the fuel line immediately after the tank lead-through.
88DU
Solenoid valve connection to the circuit board
Picture 1
Picture 2
Picture 3
- 78 -