4.5 Operation with external thermostat

When the device is controlled by an external
thermostat (or programmable thermostat), the
installer must have set configuration 1.
In this case the device shuts down when the
external thermostat is satisfied (open circuit).
The device automatically restarts when the
temperature drops below the value set on the
external thermostat (closed circuit).
Indication: During the first ignition, or if
shutdown is prompted directly from the
device, the latter must be ignited directly
from the control panel.
46

4.6 Operation with room sensor on stove

The device can be turned on/off either manually
or according to a program.
The device modulates the power based on the
room temperature detected by the on-board
sensor (it tries to maintain the desired tempera-
ture, consuming as little as possible).
If the user has enabled the "Eco-mode" function,
instead of modulating, the device shuts down
when the set temperature is reached and restarts
when the room temperature falls below the set
delta (see section "3.1.4 "Eco mode" function").
Automatic restart ...
Actual temp. 25,9°C
Fig. 66