Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Napoleon ROGUE 365 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ROGUE 365:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6
!
WARNING!
EN

Technical Data

The following table lists input values for the appliance.
Main
Side (Infra Red)
Side (Flame)
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with the following list.
Gas Category
Orifice Sizes (see
Gases / Pressures
Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table
above. For replacement, use only the regulator specified by the manufacturer.
www.napoleongrills.com
Do not route hose underneath drip pan.
Do not route hose between space in bottom shelf and back panel.
Do not route hose over top of back panel.
Ensure all connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on
any hose connection.
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing
a fire.
Do not use enclosure to store excess hose, as there is a greater chance of the hose contacting a hot
surface, it may melt and leak causing a fire.
Burner
Orifice Size
I
#59
0.86 mm
0.86 mm
I3B/P(30)
I
above)
Butane 30 mbar
Propane 30 mbar
BE, BG, CY, DK, EE, FI,
FR, GB, HR, HU, IS, IT,
Countries
LT, LU, MT, NL, NO,
RO, SE, SI, SK, TR
(Gross) Heat Input
(Total)
II
I / II
#64
9.5 kW
#69
3.0 kW
#69
3.0 kW
I3+(28-30/37)
I3P, I3B/P(37)
I
Butane 28-30 mbar
Butane 37 mbar
Propane 37 mbar
Propane 37 mbar
BE, CH, CY, CZ, ES,
FR, GB, GR, IE, IT, LT,
LU, LV, PT, SK, SI
Gas Usage (Total)
I / II
690 g/hr
218 g/hr
218 g/hr
I3B/P(50)
I
II
Butane 50 mbar
Propane 50 mbar
PL
AT, CH, DE, SK
N415-0440CE-GB-DE AUG 16.18