6 Troubleshooting
Code
Display text
H10.01
T Flow Zone A Closed
H10.02
T Dhw Zone A Open
H10.03
T Dhw Zone A Closed
H10.04
TSwimmPoolZoneA
Open
H10.05
TSwimmPoolZoneAClo
se
H10.09
T Flow Zone B Open
H10.10
T Flow Zone B Closed
H10.11
T Dhw Zone B Open
92
Description
Flow temperature sensor Zone A
Closed
Domestic Hot Water temperature
sensor Zone A Open
Domestic Hot Water temperature
sensor Zone A Closed
Swimming Pool Temperature
Sensor Zone A Open
Swimming Pool Temperature
Sensor Zone A Closed
Flow temperature sensor Zone B
Open
Flow temperature sensor Zone B
Closed
Domestic Hot Water Temperature
Sensor Zone B Open
Solution
Flow temperature sensor zone A short-circuited:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Faulty sensor: replace the sensor
Domestic hot water temperature sensor zone A
open:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Sensor is not present.
Faulty sensor: replace the sensor
Domestic hot water temperature sensor zone A
short-circuited:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Faulty sensor: replace the sensor
When using thermostat instead of sensor: pa­
rameter CP500 must be set to off (=disable)
Swimming pool temperature sensor A open:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Sensor is not present.
Faulty sensor: replace the sensor
Swimming pool temperature sensor zone A short-
circuited:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Faulty sensor: replace the sensor
Flow temperature sensor zone B open:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Sensor is not present.
Faulty sensor: replace the sensor
Flow temperature sensor zone B short-circuited:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Faulty sensor: replace the sensor
Domestic hot water temperature sensor zone B
open:
Bad connection: check the wiring and connec­
tors
Incorrectly fitted sensor: check that the sensor
has been correctly fitted
Sensor is not present.
Faulty sensor: replace the sensor