Code
Display text
EP035
Max Setp Volt
0-10V
EP046
Digital input
config
EP056
Logic level Digi
In
EP066
Req FlowSetp
digi In
EP076
Req PowSetp
digi In
NP005
Cascade
Permutation
NP006
Cascade Type
NP007
CascTOutsideH
eatParl
NP008
CascTPostRun
GenePump
NP009
CascInterStage
Time
NP010
CascTOutsideC
oolPara
NP011
CascadeTypeAl
go
NP012
CascPowerRise
Time
NP013
CascForceStop
Pprim
NP014
Cascade Mode
Tab.41
Navigation for advanced installer level
Level
Menu path
Advanced installer
Advanced installer
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
(2) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
7747028 - v.01 - 25112019
Description
Sets the maximum set point
voltage for 0 - 10 volts
Sets the general configuration of
the digital input
Sets the logic level contact of the
Smart Control Board digital input
Requested flow setpoint when
digital input is configured to
forced heat
Requested power setpoint when
digital input is configured to
forced heat
Choice of the leading
generator,.AUTO: Switching of
order every 7 days
Cascading boilers by adding
successively or in parallel, the
boilers function simultaneously
Outdoor start temperature
heating of all stages in parallel
mode
Duration of post operation of the
cascade generator pump
Switch on and switch off timing
for the producer of the cascade
Outdoor start temperature cooling
of all stages in parallel mode
Choice of Cascade Algorithm
type, power or temperature
Cascade, Time to reach
Temperature Septoint
Force Primary Pump to Stop on
cascade
Functionnement Mode of
cascade : automatic, heating or
cooling
> Submenu
> ADV
(1)
> Installation Setup > SCB-10 > Submenu
Range
0 V - 10 V
0 = Stop heating + DHW
1 = Stop heating
2 = Stop DHW
3 = Forced setpoint
4 = Buffer Tank input
0 = Open
1 = Closed
2 = Off
7 °C - 100 °C
0 % - 100 %
0 - 127
0 = Traditional
1 = parallel
-10 °C - 20 °C
0 Min - 30 Min
1 Min - 60 Min
10 °C - 40 °C
0 = Temperature
1 = Power
1 = 10
0 = No
1 = Yes
0 = Automatic
1 = Heating
2 = Cooling
> Parameters, counters, signals > Adv. Parameters
(2)
5 Settings
Submenu
Submenu
0-10 volt
input
Digital
Input
Digital
Input
Digital
Input
Digital
Input
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
Cascade
manageme
nt B
en
Default
setting
10
0
1
80
100
0
0
10
4
4
30
0
1
0
0
45