Save measurements- M00 Memory-Mode

13
Save measurements- M00 Memory-Mode
Save measurements
Display stored data
Delete records
40
HINWEIS!
The drop icon is the indication for the risk of con-
densation as well as mold warning. The buzzer
and optional vibration functions are activated at
the same time.
It is possible to store up to 50 data sets in the
device and to display them.
Measure the temperature value.
Press the Mode button repeatedly until the
memory mode M00 is called up.
Press the measuring button to save the cur-
rently displayed data set as M01.
NOTE!
After switching the device off and on again, the
stored data records are retained.
In memory mode M00, press the up/down key
until the desired data set is displayed.
To delete all records, press the Mode button
to enter Momory mode M00.
Press and hold the Up button. Now press the
down button simultaneously for 2 seconds.
Clr flashes on the display and the measured data
is deleted.