INSTRUCTION MANUAL FOR DISHWASHERS
Do not use adaptors, multiple socket outlets or cables of inadequate type and section
or with extension connections not compliant with plant engineering standards in force.
•
If the system is new or nearly so, let the water run a long time before making the connection.
•
The water supply, temperature and pressure must be compatible with what is indicated on the
machine's technical data plate.
•
If the water's hardness is greater than 14 F (8 dH), we recommend you use the machine with
internal water softener (available on request). If the water's hardness is greater than 35 F (19.5 dH),
we recommend you install an external water softener upline of the solenoid valve.
With discharge pump (available on
request)
•
There must be an omnipolar type of main switch that disconnects
all contacts, including the neutral, with a distance of at least 3 mm
between the open contacts and with safety circuit breaker tripping
or connected with fuses, to be sized or calibrated in conformity with
the power indicated on the machine's data plate.
•
The main switch must be located on the electric line close to the place
of installation, and it must serve only one appliance at a time.
•
Electric network voltage and frequency must coincide with those given
on the data plate.
•
There must be an effective earthing system in conformity with the
prevention standards in force for operator and equipment safety.
•
The power supply cable (type H07RN-F only) must not be pulled or
crushed during normal operation or routine maintenance.
•
The unipotential terminal fastened to the body must be connected to a
unipotential cable having a section suited to the application.
•
Respect the polarities indicated in the wiring diagram.
•
Consult the enclosed wiring diagram for additional information.
The appliance is to be connected to the water network with a hose. There
must be a slide on-off, ball or gate valve able to quickly and completely
turn off the water if necessary between the water network and the
appliance's solenoid valve. The on-off valve must be on the line near and
just before the appliance.
•
If the drain is not at a lower level than the base of the machine, you can
use the version equipped with a discharge pump (available on request).
•
In this case the maximum drain height is 1 m.
•
Always check that the drain works properly and that it is not clogged.
•
All other solutions must be previously agreed upon and approved by
the manufacturer.
2.3 Electrical connection
2.4 Plumbing connection
2.5 Connection to the drain line
GB