5. PROGRAMMING THE FUNCTION LOGIC
To select the function logic, press the SW1 push-button the number
of times equal to the number of the required logic, irrespective of the
current logic and the door status. The interval between the pulses
must be less than 1 second.
The selected logic is then continuously displayed by the DL1 LED,
which flashes once a second at 3 sec intervals, equal to the number
of the required logic.
To select the logics, press SW1 the number of times indicated in the
table below:
No.
Logic
Description
1
mixed B / C
B/C
2
B
Semiautomatic B
3
C
manned
EP
4
Stepped semiautomatic
(default)
5
AP
Stepped automatic
6
P
Stepped automatic
7
A
Automatic
6. START-UP
6.1.
LEDS CHECK
The following table shows the status of the LEDs in relation to the
status of the inputs (the closed at rest automated system condition
is shown in bold). If the travel-limit sensor inputs are connected to
terminal 7 (-), the FCA and FCC LEDs are always lighted. Check the
status of the signalling LEDs as per table below:
Operation of status signalling LEDs
LED
ON (closed contact)
DL1
Flashing to indicate selected logic
OP-A
Command enabled
CLOSE
Command enabled
SAFE
Safety devices disabled
STOP
Command disabled
FCA
Opening limit switch free
FCC
Closure limit switch free
6. TIME LEARNING
Time learning instructions:
1. Release the automated system and put it into closed position.
Check if the closing travel-limit sensor (if present) is engaged
(FCC LED OFF) and if the STOP and SAFE LEDs are lighted;
2. press SW1 and hold it down until the automated system begins
the opening operation;
3. Operation without travel-limit sensor: when the automated system
has reached opening position, wait 2-3 seconds and then press
SW1 again or command OPEN to stop the operator;
Operation with travel-limit sensor:the automated system will stop
automatically when the opening limit-switch is reached. After
the motor stops, the board begins to learn the extra work time
(time-out after which the board commands the motor to stop if
the stop limit-switch is not reached correctly). Wait for the time
you require (max= 10 min), and then press OPEN or SW1 to save
it;
4. if the A or AP logic is set, after completing the procedure at point
3, the board starts to learn the pause time. Wait for the pause time
you require, and then press OPEN or SW1 again to save it (max
= 5 min) and the automated system will automatically begin to
close the door;
5. if, instead, a logic other than A or AP is set, the learning stops at
point 3. To close the door, press OPEN or CLOSE, according to
the logic.
7. AUTOMATED SYSTEM TEST
When you have finished programming, check if the system is
operating correctly. In particular, check if the safety devices are
operating correctly.
SW1 PRESSINGS
once
twice
3 times
4 times
5 times
6 times
7 times
OFF (Open contact)
Command disabled
Command disabled
Safety devices engaged
Command enabled
Opening limit switch
engaged
Closing limit switch
engaged
5
8. FUNCTION LOGICS
Logic B/C
Open
Close
Status
(pulse)
(maintained)
Closed
Opens
/
Opening
/
Closes
Open
/
Closes
Closing
Opens
Closes
Locked
Opens
Closes
Logic B
Open
Close
Status
(pulse)
(pulse)
Closed
Opens
/
Opening
/
Closes
Open
/
Closes
Closing
Opens
/
Locked
Opens
Closes
Logic C
Open
Close
Status
(held)
(held)
Closed
Opens
/
Opening
Opens
Locks
Open
/
Closes
Closing
Opens
Closes
Locked
Opens
Closes
Logic EP
Open
Status
(pulse)
Closed
Opens
Opening
Locks
Open
Closes
Closing
Locks
Starts in opposite
Locked
direction (always
closes after a Stop)
Logic AP
Open
Status
(pulse)
Opens and closes
Closed
after pause time
Opening
Locks
Pause
Locks
Closing
Opens
Locked
Closes
Logic P
Open
Close
Status
(pulse)
(pulse)
Closed Opens
/
Completes opening
Opening
/
and then closes
Open
/
Closes
Closing Opens
/
Locked Opens
Closes
Logic A
Open
Status
(pulse)
Closed Opens and closes
after pause time
Completes
Opening
/
opening and
then closes
Recharges
Pause
pause time
Closing
Opens
Locked
Opens
Stop
Disables
Open and Close
Locks
Disables
Disables
Open and Close
closing
Locks
Opens
Disables
Disables
Open and Close
closing
Stop
Disables
Open and Close
Locks
Disables
Disables
Open and Close
closing
Locks
Opens
Disables
Disables
Open and Close
closing
Stop
Disables
Open and Close
Locks
Disables
Disables
Open and Close
closing
Locks
Locks
Disables
Disables
Open and Close
closing
Close
Stop
(pulse)
Disables
/
Open and Close
Closes
Locks
Disables
Disables
Closes
Open and Close
closing
/
Locks
Opens
Disables
Disables
Closes
Open and Close
closing
Close
Stop
(pulse)
Disables
/
Open and Close
Closes
Locks
Repeats
Closes
Locks
pause
/
Locks
Opens
Disables
Disables
Closes
Open and Close
closing
Stop
Disables
Open and Close
Locks
Disables
Disables
Open and Close
closing
Locks and clo-
Locks
ses on release
Disables
Disables
Open and Close
closing
Close
Stop
Safe
(pulse)
Disables
/
Open and Close
Locks
Recharges
Closes
Locks
pause time
/
Locks
Opens
Disables
Disables Open
Closes
Close
and Close
Safe
/
/
Safe
/
/
Safe
/
/
Safe
/
/
Safe
/
/
Safe
/
/
/
/