Troubleshooting

8.3 Replacing a cutting blade

Risk of injury posed by sharp blades
► Use forceps to change the blades.
► Dispose of the removed blades in a sepa-
rate container.
All present blades must be replaced each time
the knife is changed.
► Remove the protective cover and the chute.
1
2
Figure 8.1 Cutting blade
► Loosen the fixing screws (1) (Allen key 2.0 mm).
► Remove the blades (2).
► Align the new blades so that the bevelled edges are
turned away from one another.
Figure 8.2 Aligning the blades
► Insert the new blades.
► Screw both fixing screws back on tightly.
► Reattach the chute and the protective cover.
32
CAUTION

8.4 Replacing the fuses

► Make sure that the machine is switched off.
► Remove the power plug.
Figure 8.3 Opening the fuse compartment
► Lever the fuse compartment (1) out of the mains filter
unit using a slotted screwdriver.
► Replace both fuses with new ones (2 x T2AH250V).
► Put the fuse compartment back into the mains filter unit.
1