Herunterladen Diese Seite drucken

Balluff BOS 18M-P/NA-LR10 Serie Betriebsanleitung Seite 3

Optoelektronische sensoren – reflexionslichtschranke

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BOS 18M(R)-P/NA-LR10-...
Photoelectric Sensors – Retro-reflective Sensor (Laser)
User's Guide
Safety Notes
These photoelectric sensors may not be used in
applications where personal safety depends on
proper function of the devices (not safety
designed per EU machine guideline). Read
these operating instructions carefully before
putting the device into service.
CAUTION! Laser beam.
Temporary glare and eye irritation possible.
DO NOT LOOK DIRECTLY INTO THE BEAM!.
The CE Mark verifies that our products meet the
requirements of the current EMC Directive.
In our EMC Laboratory, which is accredited by
the DATech for Testing of Electromagnetic
Compatibility, proof has been documented that
these Balluff products meet the EMC require­
ments of the harmonized standard
IEC 60947­5­2.
Displays and controls
Yellow LED
Output function indicator: The LED comes on as soon as
the output is active.
Green LED
Power on indicator: The green LED indicates that the
sensor is operating and the laser is active.
Potentiometer
Used for setting the sensitivity and range. Caution! Do not
turn the potentiometer beyond the mechanical stop at
270°.
www.balluff.com
Order code
Retro reflective straight
BOS013N
BOS 18M­PA­LR10­S4S
Retro reflective right angle
BOS013Z
BOS 18MR­NA­LR10­02
BOS0145
BOS 18MR­PA­LR10­02
BOS0140
BOS 18MR­NA­LR10­S4
BOS0146
BOS 18MR­PA­LR10­S4
PNP
N.O./N.C.
NPN
N.O./N.C.
PNP
N.O./N.C.
NPN
N.O./N.C.
PNP
N.O./N.C.
Installation
CAUTION!
Do not look into the laser beam.
Locate sensor so that it is not possible to look
directly into the light source even during opera­
tion. No additional protection measures are
requiered (Laser Class 1 per IEC 60825­1:2014).
The sensor can be fixed by means of the M18x1 threaded
body through a Ø 18 mm hole, using the two nuts enc­
losed (max. 22 Nm tightening torque)
Connector version
Cable version
Fig. 1: Dimensions
connector
cable
cable
connector
connector

Werbung

loading

Diese Anleitung auch für:

Bos 18mr-p/na-lr10Bos 18mr-na-lr10-02Bos 18mr-pa-lr10-02Bos 18mr-na-lr10-s4Bos 18mr-pa-lr10-s4