Factory settings after exchange
* Analog Output D/A- Trim (customer)
* Mounting Position Correction (customer)
* Sensor Calibration / Lower, Upper Sensor Trim (customer)
Sensor Calibration / Lower Sensor Trim Point
Sensor Calibration / Upper Sensor Trim Point
Human Interface / Local display unit
Unit and measuring speed / Unit
Unit and measuring speed / Cycle time
Alarm states / AO Alarm type
Alarm states / Alarm LRV, URV
Analog Output Limits / Analog Output Lower, Upper Endpoint Value
Process Value Scale / Lower Value
Process Value Scale / Upper Value
Damping
Linearization / Transfer function
Linearization / Start-point of square-rooting
Table 2
Condition of parameters using the mode " factory calibration" (HART Device)
Condition of customer parameters
after exchange of electronic
Condition of customer parameters
after exchange of measuring cell
Parameters in SIMATIC PDM
Identification / Device / Sensor Type
Identification / Device / Sensor Serial Number
Input / Transducer Block 1 / Measuring Limits / Lower Value
Min
Input / Transducer Block 1 / Measuring Limits / Upper Value
Max
Operating Conditions / Process Conditions / Limiting Medium
Pressure Max
Diagnosis Settings / Service Interval for sensor
Mechanical Construction / Design / Sensor / Module Fill Fluid
Mechanical Construction / Design / Sensor / Isolator Material
Mechanical Construction / Design / Sensor / O-Ring Material
Mechanical Construction / Design / Remote Seal / Number of
remote seals
Mechanical Construction / Design / Remote Seal / Remote
seal type
Table 3
Condition of customer parameters after exchange. (PROFIBUS-PA Device)
A5E00078060-04
customer data
measuring cell
1)
factory data
2)
measuring cell
Service manual
Value
Like factory D/A- trim
0.0
Like factory Sensor Trim, with-
out turn down
0.0
upper sensor limit
mA
bar
90 ms
down
3.6 / 22.8 mA
3.8 / 20.5 mA
0.0
upper sensor limit
0.1 s
linear
5 %
preseted
factory data
electronic
preseted
customer data
electronic
X
X
X
X
X
X
X
X
X
X
X
49