L
sound pressure level ...................... 101 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ..................... 103.8 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 60745.
Chiseling
Vibration emission value a
h
K uncertainty = 1.5 m/s
2
The specifi ed vibration value was established in
accordance with a standardized testing method.
It may change according to how the electric
equipment is used and may exceed the specifi ed
value in exceptional circumstances.
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm
vibrations if the equipment is used over a
prolonged period or is not properly guided
Anl_TE_DH_50_SPK9.indb 18
Anl_TE_DH_50_SPK9.indb 18
GB
and maintained.
Danger!
The electric power tool generates an electro-
magnetic fi eld during operation. Under certain
circumstances this fi eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
= 22.9m/s
2

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
Before using the tool, use a to cable/pipe detector
to check the point of use for concealed electrical
cables, gas pipes and water pipes.
5.1 Additional handle (Fig. 2)
For safety reasons you must only use the
demolition hammer with the additional handle.
The additional handle (3) enables you to achieve
better stability while using the demolition hammer.
The additional handle (3) can be turned to any
required position:
To do this, undo the fastening for the
additional handle (4).
Now turn or tilt the additional handle (3) into
the most comfortable working position for you
and then tighten the fastening (4) again.
5.2 Inserting the tool (Fig. 3-4)
Before inserting it, clean the tool and lightly
grease the shaft of the tool.
1. Pull out the locking bolt (5) as far as possible
and hold it.
2. Turn it through 180° and release it. It does not
matter which direction you turn it in.
3. Guide the tool with the fl at side facing the bolt
into the tool chuck (6) and slide it in as far as
it will go.
4. Pull out the locking bolt (5) again and hold it.
5. Turn it through 180° again and release it. It
does not matter which direction you turn it in.
- 18 -