Description

3.1

Product overview

The figure shows an Air Guard 6700 HP.
Pos. Description
1
Gas outlets
2
Touchscreen with the keys F1 to F4 and a USB port on
the rear side for the data logger
3
Signal lamps
Red: Alarm A2
Yellow: Warning A1
Green: Ready for operation
Pos. Description
4
Alarm tone (optional)
5
High or medium pressure input depending on the
specification
1
6
Polytron 7000, the right-hand Polytron 7000 is optional
7
Differential pressure sensor
8
PIR 7200
9
PID 5000
10
Moisture sensor
11
Automatic purge
2
12
Pressure reducer (only in HP variants)
13
Circuit breaker
3
14
Measuring gas moisturisation
4
3.2

Feature description

5
The Air Guard continuously monitors the compressed air
quality of breathing air in accordance with the limit values in the
DIN EN 12021 standard.
Alarms are issued when limits are exceeded. The alarms are
transmitted to signal lamps at the front of the device. There are
additional potential-free contacts available (for example, to
give feedback on compressor control or the filling panel).
The Air Guard has 4 base models, each of which can be
equipped with an optional feature. The base models are:
6
Air Guard 6500 HP
Air Guard 6500 LP
Air Guard 6700 HP
Air Guard 6700 LP
6500
Measurement of CO, CO
residual oil content
7
6700
Measurement of CO, CO
8
residual oil content as well as H
9
sulphide)
LP
Maximum operating pressure: 6-10 bar
10
11
HP
Maximum operating pressure: 200-300 bar
12
The following option is available:
External visual warning (additional signal lamp, variable
13
cable length)
3.3

Intended use

Air Guard is a large-scale permanent installation which
continuously monitors the limit values for specific
14
contaminations in the connected breathing air supply using the
installed sensors. Air Guard analyses the measured values
and triggers an alarm when limit valuesare exceeded. This
alarm activates two potential-free contacts in the device which
can be used to shut down a compressor and simultaneously
lock the taps. Dräger recommends using both potential-free
contacts to make sure that contaminated air is blocked in the
case of an alarm. The alarms are also transmitted by the lamps
installed on the front of the device or by an external visual
warning (optional).
Description
en
, O
, moisture and
2
2
, O
, moisture and
2
2
S (hydrogen
2
17