Herunterladen Diese Seite drucken

T&S B-0968 Installations- Und Wartungsanleitungen Seite 5

Atmospheric vacuum breakers
Vorschau ausblenden Andere Handbücher für B-0968:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Typical Installation:
Follow the instructions in the Single
Vacuum Breaker section, Step 1 thru
step 5.
Two typical T&S unit installations
will look as follows:
B-929 Atmospheric Vacuum
Breaker Assembly
B-657
Service Sink
Faucet
Repair Kit:
1. For replacement parts, reorder
complete unit, or replace internal
parts with a repair kit for your specific
model Vacuum Breaker:
B-968-RK01 3/8" Vac. Breaker
½
B-969-RK01
2. (See exploded view shown above.)
Remove the two no.1 from top of
no.3, and lift off no.2 and no.3.
3. Unscrew and remove no.5, no.6,
no.7 and no.8 from inside no.9.
4. Replace parts with new parts from
kit.
" Vac. Breaker
B-0968-RK01 (Kit)
3/8" Vac. Breaker
5. Reassemble in reverse order.
Note: Make sure surface inside the
body (as indicated below) is clean,
and then tighten no.5 until it is
firmly seated against the inside
shoulder of no.9.
B-0969-RK01 (Kit)
o r
1/2" Vac. Breaker
make
sure
this
surface
is clean

Werbung

loading

Diese Anleitung auch für:

B-0969