0197
Digital medical thermometer MT-118
Thank you for choosing this instrument from TFA.
1. Before you use this product
• Please make sure you read the instruction manual carefully.
• Following and respecting the instructions in your manual will prevent damage to your instrument and loss of
your statutory rights arising from defects due to incorrect use.
• We shall not be liable for any damage occurring as a result of non-following of these instructions.
• Likewise, we take no responsibility for any incorrect readings or for any consequences resulting from them.
• Please take particular note of the safety advice!
• Please keep this instruction manual safe for future reference.
2. For your safety
• The unit is suitable exclusively for measuring human body temperature. The product should only be used as
described within this instruction.
• Before each measurement check intactness of tip and display. Use the unit only when intact.
• Unauthorised repairs, modifications or changes to the product are prohibited.
• Operation in strong electromagnetic fields, such as next to a mobile phone, can lead to malfunction. Keep a
minimum distance of 3.3 m from such devices when using this device.
• The minimum measurement time until the beep must be maintained without exception.
• Discuss the measured values with your doctor.
Caution!
Risk of injury:
• The instrument contains small parts that could be swallowed by children. Keep this instrument and the battery
out of reach of children. Use under parental supervision.
• Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swallowed, this can lead to
serious internal burns and death within two hours. If you suspect a battery could have been swallowed or other-
wise caught in the body, seek medical help immediately.
• Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of explosion!
• Low batteries should be changed as soon as possible to prevent damage caused by leaking.
• Wear chemical-resistant protective gloves and safety glasses when handling leaking batteries.
Important information on product safety!
• Do not place the unit near extreme temperatures, vibrations or shocks. Do not bend the instrument.
• The instrument is not waterproof. Protect from moisture.
3. Elements and buttons
A: Battery compartment
C: Display for the temperature
4. Use
• Disinfect the tip before each use!
• Press and hold the ON/OFF button for 3 seconds.
• When the unit is switched on, a beep sounds and all segments are briefly displayed. The device performs a self-
test.
• The last measured temperature (M) appears briefly on the display, then 36,5 °C.
• If you press the ON/OFF button only briefly when switching on, the last measured temperature (M) will not
appear.
• L remains on the display and °C flashes. If the room temperature is higher than 32 ˚C, the room temperature
would be displayed instead of L ˚C. The device is now ready for use.
• If the temperature remains below 32 °C, °C flashes for another 16 seconds, then the alarm signal sounds.
• The actually measured maximum temperature is permanently shown during the measurement and °C flashes.
• If the maximum temperature remains stable, °C stops flashing and an alarm will sound:
a) Normal alarm (beep ... beep ... beep ...), body temperature below 37.8 °C
b) Fever alarm (beep piep beep ... beep beep beep ...), body temperature 37.8 °C or above
• For axillary measurements, the recommended measuring time has to be observed despite the beep tone.
• Remove the thermometer carefully. Press the ON/OFF button to switch off the instrument. The instrument will
turn off automatically after approx. 9 minutes.
4.1 Measurement methods
Rectal measurement:
• This is the safest method of measurement. It is especially good for babies and infants. Gently insert the ther-
mometer tip 2-3 cm into the anus. Minimum measuring time: 1 minute.
Oral measurement:
• Oral measurement is not recommended for children younger than 2 years of age. Place the temperature tip in
one of the two pockets under the tongue, left or right at the root of the tongue. Close your mouth during the
measurement and breathe calmly. This will prevent the measurement results from being falsified by breathing
air. The measured temperature is on average 0.3 to 0.8 degrees C lower than the rectally measured temperature.
Minimum measuring time: 1 min.
Axillary measurement (under the armpit):
• From the medical point of view this method always provides inaccurate values. A deviation from the rectal
measurement of 0.5 to 1.5 degrees C must be expected. Minimum measuring time: 5 min.
5. Care and maintenance
• Clean the instrument before and after each use with a soft damp cloth. For disinfection please use water-diluted
isopropyl alcohol according to the manufacturer's instructions. Any other cleansing substances or cleansing
method can cause dysfunction or damage to the instrument. Do not immerse in water or sterilize by boiling
method, gas or steam autoclaves.
• Remove the battery if you do not use the product for a long period of time.
• Keep the instrument in its case in a dry place.
5.1 Battery replacement
• Change the battery when the display starts to fade or the battery symbol appears on the display.
• Remove the battery cover by pulling it backwards.
9:54 Uhr
Seite 2
B
A
C
B: ON/OFF button
D: Temperature probe
Instruction manual
Digital medical thermometer MT-118
• Carefully remove the battery with a pointed object and insert a new LR 41 battery. Make sure the polarity is correct
(+ pole above).
• Do not pull out the battery holder. Otherwise the device may be damaged.
• Slide back the battery cover. Pay attention to the sealing ring.
6. Troubleshooting
Problem
Solution
➜ Switch on the instrument
No display
➜ Ensure battery polarity is correct (+ pole above)
➜ Change the battery
➜ Change the battery
Incorrect display
➜ Check the correct position of the thermometer
(see: Measurement methods)
➜ Remove the battery. Wait one minute and then reinsert the battery
Display E
If your device fails to work despite these measures, contact the retailer where you purchased the product.
7. Legal basis for placing of the product in the EU market
• The Digital Thermometer MT-118, Art.-No. 15.2008 is a medical device class 2a according the EU Medical Device
Directive 93/42/EWG. The Digital Thermometer meets the requirements of the standards EN 12470-
3:2000+A1:2009, EN 60601-1:2006+A1:2013, EN 60601-1-11:2015, EN 60601-1-2:2015, EN 60601-1-6:2010+A1:2015,
EN ISO 15223-1:2016, EN ISO 10993-1,-5:2009, EN ISO 10993-10:2010, EN ISO 14971:2012.
8. Waste disposal
This product has been manufactured using high-grade materials and components which can be recycled and
reused.
Never dispose of empty batteries and rechargeable batteries in household waste.
As a consumer, you are legally required to take them to your retail store or to appropriate collection
sites depending on national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are: Cd=cadmium, Pb=lead, Hg=mercury
This instrument is labelled in accordance with the EU Waste Electrical and Electronic Equipment
Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is obligated to take end-of-life
devices to a designated collection point for the disposal of electrical and electronic equipment, in
order to ensure environmentally-compatible disposal.
9. Specifications
Type:
Maximum thermometer
Measuring range:
32 °C...44 °C
Display L °C
Surrounding temperature lower than 32 °C
Display H °C
Surrounding temperature higher than 44 °C
Accuracy:
±0.1 °C at 35 °C...39 °C
otherwise ±0.2 °C
Resolution:
0.1 °C
Storage and transport conditions:
Temperature -10 °C...+60 °C / humidity: 25... 90 % rH
Ambient conditions by use:
Temperature 10 °C...40 °C / humidity: 30...85 % rH
IP protection class:
IP22
Battery:
LR 41 included
Average battery life:
2 years
Housing dimension:
19 x 10 x 124 mm
Weight:
10 g (instrument only)
10. Explanation of symbols
Declaration of European conformity, number of the notified body (TÜV Rheinland)
0197
Device complies with protection class BF
Storage and transport conditions:
Temperature: -10 °C...+60 °C
Humidity: 25...90 % rH
Lot number
Manufacturer: Vega Technologies Inc., Yangwu District, Dalang Town, Dongguan City, Guangdong, China
EU Representative: Biolife Ltd., No.332, Kifisias Av., 15235 Halandri, Athens, Greece
Importer: TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going
to print and may change without prior notice. The latest technical data and information about this product can be found in our homepa-
ge by simply entering the product number in the search box.
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
Made in P.R.C.
Art.-No.15.2008
Consult instructions for use
Ambient conditions by use:
Temperature: +10 °C...+40 °C
Humidity: 30...85 % rH
04/2020D/GB

Werbung

loading