EFE300M Handbook
CAUTION: DOUBLE POLE/NEUTRAL FUSING
The (+) or (-) output(s) can be earthed or left floating.
The unit cover(s)/chassis (where applicable) must not be made user accessible.
The mains input connector is not acceptable for use as field wiring terminals.
For encased products, do not use mounting screws, which penetrate the unit more than 4.5mm.
Internal fuses protect the unit and must not be replaced by the user. In case of internal defect, the unit must
be returned to TDK-Lambda UK LTD or one of their authorised agents.
WARNING: These products are Class 1 and must therefore be reliably earthed and professionally installed in
accordance with the prevailing electrical wiring regulations and the safety standards covered herein.
For uncased models, H1 to H4 must be connected to protective earth. H1 to H4 fixing screw head/washer
diameter must not exceed 6mm.
A suitable mechanical, electrical and fire enclosure must be provided by the end use equipment for
mechanical, electric shock and fire hazard protection.
Energy Hazards:
The main output of this product is capable of providing hazardous energy (240VA). Final equipment
manufacturers must provide protection to service personnel against inadvertent contact with the output
terminals.
The ventilation openings on these products must not be impeded. Ensure that there is at least 50mm spacing
between any obstruction and the ventilation openings.
The unit cover/chassis, where applicable, is designed to protect skilled personnel from hazards. They must
not be used as part of the external covers of any equipment where they may be accessible to operators, since
under full load conditions, part or parts of the unit chassis may reach temperatures in excess of those
considered safe for operator access.