Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
Assembly (see page 33)
English
Adjustment (see page 35)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance (see page 42)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions (see page 36)
Flow diagram (see page 36)
Shower outlet
Tub outlet
Spare parts (see page 38)
Cleaning (see page 41)
®
Operation (see page 40)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
Test certificate (see page 42)
65°C
Remedy
- Clean aerator, replace as
necessary
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter