Descaling the boiler
1
Take special care to ensure that the appliance is cold and
unplugged.
2
Empty the water tank.
3
Remove the iron from the pad (12).
4
Unscrew and remove the boiler cap (9) and take it out.
Empty the boiler completely.
5
Fill the boiler with approximately 300 ml of tap water.
Close the boiler cap and shake the base unit for a few
moments. Then, empty it completely.
Important: To obtain the best result, we recommend that
this operation be performed twice.
Before re-closing, make sure no water remains in the boiler.
6
If your appliance is equipped with scale collector (9*), it
must be washed (see the "Descaling the scale collector"
section).
7
Replace and tighten up the cap.
Descaling the limescale collector *
1
Place the limescale collector under the water tap.
2
Wash it up until limescale residues are removed.
Descaling the iron
2"
1
Fill the tank (10) with tap water.
2
Plug in the mains cable (7) and press the button (2) to
switch the appliance on.
3
Press the descaling button (3) for 2 seconds. Its indicator
light will remain permanently lit.