SW230.T / SW230.T.120
Electrical connection with photo-test function active.
With Dip switch 10 ON, programmable input P.OUT controls the operation of the safety devices.
Stop push button connection.
Input STOP is normally closed. The opening of the contact causes the gate to stop and the automatic closing time to be suspended. If not used jumper
between COM and STOP. With the push button not engaged, LED DL2 must be on.
N.B.: if there are no photocells, sensitive edges or stop push buttons in the system, inputs STOP, SCL, SOP must be jumpered with COM and Dip
switches 10, 11 and 12 must be set to OFF.
Open push button connection.
Input P.IN with Dip switch 11 set to OFF is normally open. The closing of the contact causes the gate to open.
With the push button not engaged, LED DL6 must be off.