Setting the input
impedance
(Impedance)
Downloaded from
www.Manualslib.com
Miniature switches „2" are used to set the desired input impedance for the
left (2L) and right (2R) channels.
The information you need for this will be included in the manufacturer's
specification for the pick-up system you intend to use.
Select the value which is closest to the manufacturer's stated figure. It is
essential to set the same value for both channels.
If you do not have access to the manufacturer's specification, a good
starting point for input impedance is 100 . This is the factory default
setting.
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
manuals search engine
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
21
Input impedance []
450 
650 
...
200 
449 
...
130 
199 
...
85 
129 
...
50 
84 
...
30 
49 
...
20 
29 
...
16 
19 
...
15 
<
Table 4